A clinical appraisal of the vectorcardiogram in myocardial infarction. II. The Frank system.

نویسندگان

  • P G HUGENHOLTZ
  • C E FORKNER
  • H D LEVINE
چکیده

IT HAS BEEN ARGUED that the vectorcardiogram should yield no more information than a standard 12-lead electrocardiogram. Yet many authors, including Wolff," 2 Burch,3-5 Scherlis and Grishman6 and Milnor,7 employing different lead systems, have published data indicating that the vectorcardiogram may demonstrate abnormalities not apparent in the electrocardiogram. Of a total of 2,545 vectorcardiograms recorded over a 2-year period in patients hospitalized at the Peter Bent Brigham Hospital 368 fulfilled the criteria, to be described below, for the diagnosis of myocardial infarction. Sixty-seven of these patients were subsequently examined post mortem. The 368 recordings fell into two groups, one in which the Grishman cube8 (161 cases) was employed, the other in which the corrected lead system of Frank9 (207 cases) was used. This communication will deal exclusively with the results obtained by the former technic. Based upon the results of a correlation between anatomic and vectorcardiographic findings, a division into distinct groups of vectorcardiographic patterns was established and these were expressed in numerical values. In addition an evaluation was made of the accuracy of the vectorcardiogram recorded by the cube

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Clinical Appraisal of the Vectorcardiogram

IN THE preceding communication' the results of the vectorcardiographic examination of 161 cases of myocardial infarction employing the cube system2 were described. In the present report the results are given for 206 cases studied by the Frank system. The purpose of this study is to determine the practical value of this corrected lead system, which has been reported to possess many theoretical a...

متن کامل

A Clinical Appraisal of the Vectorcardiogram in Myocardial Infarction

IT HAS BEEN ARGUED that the vectorcardiogram should yield no more information than a standard 12-lead electrocardiogram. Yet many authors, including Wolff," 2 Burch,3-5 Scherlis and Grishman6 and Milnor,7 employing different lead systems, have published data indicating that the vectorcardiogram may demonstrate abnormalities not apparent in the electrocardiogram. Of a total of 2,545 vectorcardio...

متن کامل

A Clinical Appraisal of the Vectorcardiogram

IT HAS BEEN ARGUED that the vectorcardiogram should yield no more information than a standard 12-lead electrocardiogram. Yet many authors, including Wolff," 2 Burch,3-5 Scherlis and Grishman6 and Milnor,7 employing different lead systems, have published data indicating that the vectorcardiogram may demonstrate abnormalities not apparent in the electrocardiogram. Of a total of 2,545 vectorcardio...

متن کامل

Clinicopathological study in an ovine model of experimental acute myocardial infarction

To evaluate the prognostic significance of clinicopathological measurement in the diagnosis of acute myocardial infarction (MI) in sheep, acute MI was induced by ligation of left anterior descending coronary artery (LAD). For this purpose, twenty four healthy sheep were divided into the sham-operated or control group (group I, thoracotomy without MI) and the experimental group (group II, with M...

متن کامل

The Frontal Plane Vectorcardiogram

The mid-to-late part of the frontal plane QRS loop (Frank lead system) of 150 consecutive subjects with an old inferior myocardial infarction was analyzed. During the acute episode all cases had to satisfy Myers' classical ECG criteria for the diagnosis. The vectorcardiogram was recorded months to years later. As a result of this analysis and in order to prevent overlap with values found in 450...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 24  شماره 

صفحات  -

تاریخ انتشار 1961