Offline test of a Cryogenic Stopping Cell for the Low-Energy Branch of the Super-FRS at FAIR
نویسندگان
چکیده
Here we report the first successful offline test of the cryogenic gas stoping cell developed for the low-energy branch of the Super Fragment Separator (Super-FRS) at FAIR in Darmstadt, Germany. This gas cell has a stopping volume of length 1 m and diameter 0.25 m. A DC field throughout the length of the cell and a RF carpet with DC field superimposed at the exit side to guide the ions towards the exit-hole without hitting the wall are opted to ensure the fast and efficient extraction of the ions stopped throughout the volume of the cell (Figure 1). Once the ions reach the exit hole, the gas flow will drag them out of the stopping volume. Extensive simulations were performed to guide the design of the DC and RF ion guides of the stopping cell [1].
منابع مشابه
A Time-of-Flight-Based Isobar Separator and Mass Spectrometer for the LEB
At the Low-Energy-Branch (LEB) of the Super-FRS at FAIR, precision measurements of very short-lived nuclei will be performed. For these experiments (MATS, LASPEC), the nuclei have to be stopped, cooled, separated and measured as fast and efficiently as possible. To achieve this goal, a multi-purpose, non-scanning mass spectrometer with single-ion sensitivity, a multiple-reflection timeof-flight...
متن کاملThe Comparison of the shares of stopping power in a soft tissue-equivalent material
Introduction: Proton therapy is a type of radiation treatment that it uses protons to treat cancer. Because of the protons’ unique ability to distribute the radiation dose more directly to the tumor, it minimizes the damage to nearby healthy tissues. The rate of energy loss by the ion in the target is called stopping power. The total stopping power is sum nuclear and electroni...
متن کاملThe effect of deep cryogenic treatment on mechanical properties of 80CrMo12 5 tool steel
Cryogenic treatment can be used as a supplemental treatment that is performed on some tool steels between quenching and tempering as an effective method for decreasing retained austenite and increasing wear resistance. In this research, the effect of deep cryogenic treatment (DCT) on dimensional stability and mechanical properties of 80CrMo12 5 tool steel was investigated. The martensitic trans...
متن کاملA Multiple-Reflection Time-of-Flight System for Mass Measurements and Isobaric Separation for SHIPTRAP and the LEB of the Super-FRS at FAIR
At low-energy radioactive ion beam facilities such as SHIPTRAP and the Low-Energy Branch of the Super-FRS at FAIR, mass measurements and spectroscopy for a broad range of nuclei can be performed. Access to these nuclei is limited by their lifetime and the amount of isobaric contamination. To help to overcome these limitations, a multiplereflection time-of-flight mass spectrometer (MR-TOF-MS) sy...
متن کاملThe Mathematical Method and Thermodynamic Approaches to Design Multi-Component Refrigeration used in Cryogenic Process Part II: Optimal Arrangement
A refrigeration cycle is a chain of various pieces of equipment including compressors, condensers, evaporators, and expansion devices each of which takes on a particular thermodynamic process duty in the cycle that eventually results in the production of the required refrigeration. The results of optimized mixed refrigerant cycles (MRCs) in Part I show that the configuration of MRC is an eff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011