Effects of analytical method and lyophilized sera on measurements of apolipoproteins A-I and B: an international survey.

نویسندگان

  • S J Smith
  • L O Henderson
  • W H Hannon
  • G R Cooper
چکیده

In 1987 a collaborative study was initiated with 140 laboratories worldwide to evaluate the effects of analytical method and lyophilization on the measurement of different concentrations of apolipoproteins (apo) A-I and B in four lyophilized serum pool samples. This survey confirmed that the lyophilized apo Reference Material of the International Union of Immunological Societies (IUIS) is useful for apo A-I assays as an international serum-based reference material, because among-method variation is negligible. The apo A-I concentration value of 1.24 g/L is now assigned to the IUIS Reference Material (CDC 1883) by a Centers for Disease Control RIA in-house reference method. Use of lyophilized serum preparation as a reference material for some modes of apo B measurement is questionable because of lyophilization and matrix effects. Both radial immunodiffusion and liquid immunoprecipitin methods demonstrated bias in measured apo B concentrations, compared with overall method-weighted means values on the IUIS Reference Material. Because of the uncertainty associated with LDL primary standard, protein analysis, and concentration differences among analytical methods, assigning a single apo B concentration value to the IUIS Reference Material appears inadvisable at present.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

International survey of apolipoproteins A1 and B measurements (1983-1984).

We report here results of a worldwide survey of apolipoprotein (apo) A1 and B measurements. A lyophilized pool of human serum was developed for the survey to test its suitability as a candidate Reference Material. Seventy-five laboratories from 18 countries responded to invitations to participate. Using several methods, they evaluated the mass concentration of apo A1 and B in the proposed Refer...

متن کامل

Effects of lyophilization of serum on the measurement of apolipoproteins A-I and B.

A common accuracy-based standardization program is indispensable for establishing reference intervals for the clinical use of apolipoproteins. The development and distribution of reference materials and quality-control materials that do not exhibit matrix effects between methods is essential to the standardization process. We examined the suitability of lyophilized material as a common referenc...

متن کامل

An international collaborative study on standardization of apolipoproteins A-I and B. Part II. Evaluation of contributions of antisera to among-laboratory variance components.

Local antisera (LA) were compared with a common interim reference antiserum (IRA) to examine the antiserum component of the among-laboratory variation in an international collaborative study with 28 laboratories evaluating a candidate international Reference Material (apo-RM) for apolipoproteins A-I (apo A-I) and B (apo B). Measurement of the relative concentration of lyophilized preparations d...

متن کامل

Effects of Ramadan Fasting on Apolipoproteins A and B and Atherogenic Index in Fasting and Non-Fasting Students

Purpose: Several studies have been done on the effects of fasting on human health indicating the beneficial effects of fasting on weight control, lipid metabolism, and lowering blood pressure in healthy people. The present study aimed at investigating the effects of Ramadan fasting on apolipoproteins A and B (apo A and B) and the atherogenic index of the fasting and non-fasting students. Metho...

متن کامل

International Federation of Clinical Chemistry standardization project for measurements of apolipoproteins A-I and B.

To minimize differences in apolipoprotein measurements among laboratories and methods, a standardization program involving common suitable reference material is needed. The Committee on Apolipoproteins of the International Federation of Clinical Chemistry initiated a collaborative study for the standardization of test systems for measuring apolipoproteins (apo) A-I and B, with 25 company labora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 1990