Comparison of T2-weighted and fluid-attenuated inversion-recovery fast spin-echo MR sequences in intracerebral AIDS-associated disease.
نویسندگان
چکیده
PURPOSE To compare the value of fast fluid-attenuated inversion-recovery (FLAIR) with T2-weighted fast spin-echo MR imaging in the detection of acquired immunodeficiency virus (AIDS)-related lesions of the brain. METHODS Forty-four human immunodeficiency virus (HIV)-positive patients were examined with both sequences on either a 1.0-T or a 1.5-T MR system. The number, size, location, and conspicuity of the lesions were evaluated by two independent observers. Contrast ratios between lesions and normal brain/cerebrospinal fluid were determined, and contrast-to-noise ratios were calculated. RESULTS FLAIR was found to be superior to T2-weighted fast spin-echo in detection of small lesions and of lesions located in cortical/subcortical regions and deep white matter. The two techniques were equal in delineation of lesions larger than 2 cm and for lesions located in the basal ganglia and posterior fossa. In 24 patients, more lesions were detected with the FLAIR fast spin-echo technique. Lesion/cerebrospinal fluid contrast ratios and contrast-to-noise ratios were significantly higher for the FLAIR fast spin-echo sequences than for the T2-weighted fast spin-echo sequences. CONCLUSION FLAIR allows early detection of small lesions in subcortical and cortical locations, especially in HIV encephalitis. Because of its improved lesion detection rate and greater overall lesion conspicuity, we believe FLAIR is useful in the evaluation of subtle changes in the brains of AIDS patients with central nervous system disease, and could even replace the T2-weighted fast spin-echo technique.
منابع مشابه
Adult cerebrovascular disease: role of modified rapid fluid-attenuated inversion-recovery sequences.
PURPOSE To compare a rapid fluid-attenuated inversion-recovery (FLAIR) sequence with T1-weighted, fast spin-echo proton density-weighted, and T2-weighted images in the evaluation of cerebrovascular disease. METHODS All patients underwent standard T1-, proton density-, and T2-weighted fast spin-echo and fast FLAIR MR imaging at 1.5 T. Images were compared for lesion size, location, and conspic...
متن کاملFast fluid-attenuated inversion-recovery MR of intracranial infections.
PURPOSE To assess the usefulness of fast fluid-attenuated inversion-recovery (FLAIR) MR sequences in the diagnosis of intracranial infectious diseases. METHODS We compared fast FLAIR images with conventional spin-echo images (T1- and T2-weighted) obtained in 20 patients with infectious diseases (six with encephalitis, five with brain abscesses, three with meningitis, two with meningoencephali...
متن کاملSpinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...
متن کاملT2 relaxation measurements in X-linked adrenoleukodystrophy performed using dual-echo fast fluid-attenuated inversion recovery MR imaging.
SUMMARY The purpose of this study was to determine whether dual-echo fast fluid-attenuated inversion recovery MR imaging and corresponding T2 brain maps can show different zones in the affected white matter of patients with cerebral X-linked adrenoleukodystrophy. Ten male patients with cerebral X-linked adrenoleukodystrophy underwent imaging performed using dual-echo fast fluid-attenuated inver...
متن کاملA comparison of MR sequences for lesions of the parotid gland.
PURPOSE To compare six MR sequences (plain and gadolinium-enhanced fat suppressed T1-weighted spin echo, T2-weighted standard spin echo, fat-suppressed and non-fat-suppressed T2-weighted fast spin echo, and inversion-recovery T2-weighted fast spin echo) in their ability to detect, delineate, and characterize lesions of the parotid gland. METHODS Fifty-eight parotid gland lesions imaged on 47 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 18 9 شماره
صفحات -
تاریخ انتشار 1997