A Novel Method for Measuring Saccade Profiles Using the Scanning Laser Ophthalmoscope
نویسندگان
چکیده
Most existing techniques for accurately measuring angular eye position vs time during a saccade (the saccade profile) need either contact to the eye or are restricted in time resolution. In this paper we introduce a new noninvasive method, with high spatial and temporal resolution, for determining saccade profiles using a scanning laser ophthalmoscope (SLO). This method uses the fact that images of a moving object taken with the SLO are not blurred (as are images from video cameras) but show a tilt with respect to images of the same stationary object. A mathematical framework is given that allows determination of a saccade profile from a restricted number of consecutive SLO video fields of the fundus during a saccade. The angular resolution obtained by this method is below 0.1 deg, and the maximum time resolution near 1 msec. Measured saccade profiles could be well approximated by a gamma function, the first derivative of which yields the saccade velocity profile. Measurements of peak saccade velocity as a function of saccade amplitudes (main sequence) using our method show good agreement with results obtained by other authors.
منابع مشابه
Tracking retinal motion with a scanning laser ophthalmoscope.
The vast majority of people with low vision retain some functional vision to perform everyday tasks. To study the effectiveness and efficiency of the visual tasks performed by people with low vision, knowing the movement patterns of their preferred retinal locus (PRL) used for fixation, saccade, and pursuit is critical. The scanning laser ophthalmoscope (SLO) has been used to acquire retinal im...
متن کاملVisual Acuity Measurement With a Second - Generation Scanning Laser Ophthalmoscope
Individuals with longstanding macular scotomas use an idiosyncratic, non-foveal retinal area adjacent to the scotoma to fixate and to inspect detailed visual stimuli (1). It is not known whether this preferred retinal locus (PRL) "selected" by the patient is the retinal area of highest residual visual acuity or how acuity is modified in retinal areas surrounding the scotoma. Because this inform...
متن کاملEffect of Cooling on Bending Angle and Microstructure in Laser Tube Bending with Circumferential Scanning
Laser tube bending is a flexible forming process. Two irradiation methods of axial and circumferential scanning are generally used to form metal tubes. The two most important disadvantages of circumferential scanning are its lower bending angle and the time interval required between each scan for cooling purpose. In this research, a novel cooling strategy during laser tube bending with circumfe...
متن کاملP58: Visual Working Memory Performance Based on Saccades in Children with and without Specific Learning Disorder: An Eye-Tracking Study
Some of the previous studies show that children with SLD have deficits in visual processing and working memory. Hence, the aim of this research was to investigate problems of visual working memory based on behavioral neuroscience method, using an eye tracker device. The method of present study was ex-post facto study. The participants included couple of twelve children with SLD (mean age=10.92)...
متن کاملScanning laser densitometry and color perimetry demonstrate reduced photopigment density and sensitivity in two patients with retinal degeneration
PURPOSE To test the feasibility of scanning laser densitometry with a modified Rodenstock scanning laser ophthalmoscope (SLO) to measure the rod and cone photopigment distribution in patients with retinal diseases. METHODS Scanning laser densitometry was performed using a modified Rodenstock scanning laser ophthalmoscope. The distribution of the photopigments was calculated from dark adapted ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 36 شماره
صفحات -
تاریخ انتشار 1996