Effective Assessment of Diabetes Control Using Personal Glucometers (CONTOURLINK, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA)

نویسندگان

  • R. Chlup
  • B. Doubravova
  • J. Bartek
  • J. Zapletalova
  • O. Krystynik
  • V. Prochazka
چکیده

Aim of this trial was to assess (1) the accuracy and precision of electrochemistry-based glucometers CONTOURLINK, CALLA, and LINUS and (2) the diabetes control using Ambulatory Glycaemic Profiles (AGP) as markers of therapeutic effectiveness. Glucometers and COBAS INTEGRA 400 Plus analyzer were used by one laboratory professional to estimate P-glucose (PG) in 112 out-patients. There were 112 sets of 12 PG estimations analyzed. In each set, means of 3 capillary PG estimations on 3 respective glucometers and on INTEGRA analyzer were calculated. The statistical program SPSS, v. 15, was applied. The mean INTEGRA PG values ranged from 2.7 to 25.3 mmol/L. There were strong correlations between mean PG on INTEGRA versus CONTOURLINK, versus CALLA, and versus LINUS; PG deviations from INTEGRA were mostly within the range ±15%. Wilcoxon Signed Rank Test revealed differences between CONTOURLINK-INTEGRA and LINUS-INTEGRA; CALLA-INTEGRA showed no difference. SD INTEGRA = 0.061 mmol/L, SD CONTOURLINK/SD CALLA/SD LINUS were 0.256/0.290/0.286 mmol/L. All patients were trained to perform defined 10-point PG profiles to adapt food, exercise, and insulin doses. The PG differences between all tested glucometers and reference values were in borderline of ISO 15197 but worthy of consideration. AGP are helpful markers of diabetes control.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood glucose meters employing dynamic electrochemistry are stable against hematocrit interference in a laboratory setting.

BACKGROUND Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electr...

متن کامل

Benefits of three-month continuous glucose monitoring for persons with diabetes using insulin pumps and sensors.

BACKGROUND The latest Paradigm 722 insulin pump, Medtronic MiniMed, USA, enables daily reading of 288 interstitial fluid glucose concentrations determined by a sensor inserted into subcutaneous tissue; the sensor signals are transmitted into the insulin pump, enabling the patient to see real-time glucose concentration on the display and adapt further treatment. AIMS To assess the evolution of...

متن کامل

Effect of fluoride-containing tubes on accuracy of glucometers.

G lucometers are used to quickly obtain glucose concentrations in the hospital and at home. For quality assurance, the American Diabetes Association recommends periodically comparing the results from glucometers with those from referenced laboratories (1). Usually, measurement using glucometers is done one-by-one by technicians, which is costly regarding manpower. In contrast, measurement using...

متن کامل

Chapter 11 11 Policy , Financing andImplementation Coordinating

Contributing Authors: Douglas Arent (USA), Greg Arrowsmith (Belguim/United Kingdom), Morgan Bazilian (Austria/USA), Lori Bird (USA), Thomas Boermans (Germany), Alex Bowen (United Kingdom), Sylvia Breukers (The Netherlands), Thomas Bruckner (Germany), Sebastian Busch (Austria/Germany), Elisabeth Clemens (Norway), Peter Connor (United Kingdom), Felix Creutzig (Germany), Peter Droege (Liechtenstei...

متن کامل

Reward‐based, task‐setting education strategy on glycemic control and self‐management for low‐income outpatients with type 2 diabetes

AIMS/INTRODUCTION The purpose of the study was to determine the feasibility and effect of a reward-based, task-setting strategy for low-income outpatients with type 2 diabetes. MATERIALS AND METHODS Indigent diabetes outpatients without glucometers were eligible to participate in this trial. A total of 132 cases were randomly recruited. Participants in group B used glucometers for self-monito...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2013