Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder.
نویسندگان
چکیده
BACKGROUND The design of devices currently used for closure of persistent ductus arteriosus (PDA) with high pulmonary artery pressure is not ideal and there is a risk of embolisation into the aorta. OBJECTIVE To investigate the use of the Amplatzer muscular ventricular septal defect occluder (AMVSDO) for treatment of PDA with high pulmonary artery pressure. PATIENTS AND DESIGN Seven patients, aged 5-12 years, with large PDAs and systemic or near systemic pulmonary artery pressure underwent attempted transcatheter closure using the AMVSDO. The device consists of two low profile disks made of a nitinol wire mesh with a 7 mm connecting waist. Balloon occlusion of the duct was performed before closure from the venous side, and prosthesis size was chosen according to the measured diameter of the occluding balloon. A 7 French sheath was used to deliver the device. All patients underwent a complete haemodynamic and angiographic study one year after occlusion. RESULTS The mean (SD) angiographic PDA diameter was 9.8 (1.7) mm (range 7-13 mm) and the mean AMVSDO diameter was 11.4 (1.8) mm (range 9-16 mm). Q(p)/Q(s) ranged from 1.9-2.2 (mean 2.0 (0.1)). Successful device delivery and complete closure occurred in all patients (100% occlusion rate, 95% confidence interval 59.04% to 100.00%). Mean systolic pulmonary artery pressures were as follows: before balloon occlusion, 106 (13) mm Hg; during occlusion, 61 (6) mm Hg; immediately after the procedure, 57 (5) mm Hg; and at the one year follow up catheterisation, 37 (10) mm Hg. Fluoroscopy time was 10.4 (4.3) min (range 7-18 min). No complications occurred. CONCLUSIONS AMVSDO is an important adjunct for closure of large PDAs associated with high pulmonary artery pressure. Further studies are required to document its efficacy, safety, and long term results in a larger number of patients.
منابع مشابه
Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.
Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the ...
متن کاملHybrid technique for ventricular septal defect closure in a dog using an Amplatzer® Duct Occluder II.
A left-to-right shunting muscular ventricular septal defect (VSD) was diagnosed in a 4-month-old, female, 1.8 kg Bichon Frise - poodle mix dog. Echocardiographic evidence of cardiac remodeling, calculated pulmonary blood flow (Qp) to systemic blood flow (Qs) ratio of 2.8, and radiographic evidence of pulmonary edema supported the diagnosis of a hemodynamically important VSD. Using a combination...
متن کامل[Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].
The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the def...
متن کاملTranscatheter Closure of Persistent Ductus Arteriosus Using the Amplatzer Duct Occluder in Infants
Background: Despite technical improvements over the years, interventional closure of persistent ductus arteriosus in infants remains a challenge. Objectives: To assess safety, efficacy, and follow up results of closure of symptomatic persistent ductus arteriosus in infants using the self-expanding and repositionable Amplatzer device. Setting: Queen Alia Heart Institute (QAHI), a tertiary cardia...
متن کاملTranscatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus
Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients' defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Heart
دوره 87 3 شماره
صفحات -
تاریخ انتشار 2002