Localization Profile Correction for ERETIC based in vivo H MRSI quantification

نویسندگان

  • Niklaus Zoelch
  • Alexander Fuchs
  • Anke Henning
چکیده

Introduction Magnetic resonance spectroscopic imaging (MRSI) enables the acquisition of quantitative metabolite distribution maps with internal water referencing (IWR) [1] being the current method of choice for signal normalization and determination of mM concentrations. IWR accounts for B1 variations across the field of view but imposes problems when assessing diseases that lead to alteration of tissue water concentration [2] and relaxation behavior. ERETIC (Electrical REference To access Invivo Concentrations) has proven to be a reliable and accurate alternative for the quantification of metabolite concentrations in vivo in single voxel H MRS [3] and an initial MRSI implementation has been presented previously [4]. ERETIC is independent of the disease state, automatically compensates for changes in coil loading conditions, receive gain settings and data processing and hence requires only a one time calibration against a high precision phantom. However, the combined effect of B1 inhomogeneity across the volume of interest and slice profiles of the selective RF pulses used for localization create a localization profile that induces spatially varying metabolite intensities independent of physiological changes. This effect needs to be corrected for in case of ERETIC based MRSI quantification. Hence, in this work, two localization profile correction methods for ERETIC based H MRSI quantification are presented and cross-validated against IWR based H MRSI. Materials and Methods Acquisition: In vivo and in vitro experiments were performed on a Philips Achieva 3T human MRI scanner (Philips Healthcare, Best, Netherlands) using a commercial transmit/receive birdcage proton coil with additional modifications to allow for ERETIC [3]. 2D MRSI (TR/TE: 2000/39ms) data were obtained from a 12 mm slice; 22 x 20 phases encoding steps over a FOV of 220 mm x 200 mm were applied. A VOI of 100 mm x 80 mm was preselected with PRESS, using the FREMEX05 RF pulse for excitation and the FMREF07 for refocusing. In vitro measurements were carried out in a spherical homogenous phantom containing brain metabolites. In vivo MRSI data were acquired in a healthy volunteer from an axial slice above the ventricles that included white matter of the centrum semiovale and gray matter along the interhemispheric fissure. Inner volume suppression was applied to avoid chemical shift displacement and render localization volumes consistent across all metabolites of interest. A T1-weigthed FFE image was acquired over a 36 mm slice centered at the MRSI slice position with an acquisition matrix of 220x200x9, (TR/TE 92/4.6ms) and used for tissue segmentation performed using SPM8. 3D actual flip angle maps were measured using the 3D AFI method [5]. The maps were recorded over a 108 mm wide stack with 9 slices centered at the MRSI slice and matching its FOV in the axial plane. In this way no slice profile corrections [6] had to be applied to the AFI maps itself. Resulting segmentation maps as well as flip angle maps were smoothed to the same effective resolution as the MRSI data, by convolving them with the PSF of the MRSI data. Quantification: All the spectra were eddy current and phase corrected and fitted using LCModel using simulated metabolite basis sets. The fitted resonance areas were corrected for relaxation attenuation and for partial volume effect due to CSF. IWR was carried out as described by Gasparovic et al. [7]. With ERETIC, the areas of the metabolite resonances are converted into concentrations by comparing them to an externally generated signal, that is inductively coupled into the receive coil [3]. Localization profile correction (ACP and BSP): To correct for the localization profile, the observable magnetization in every voxel under the given experimental conditions has to be estimated for a homogenous material. The correction of the metabolite/ERETIC ratio is then simply accomplished by division by the expected values for the observable magnetization. In this work these values are either calculated analytically (abbreviated ACP hereafter), using the formula from Moonen et al. [8] or by performing a Bloch simulation of the PRESS sequence with the relevant pulse and gradient waveforms (abbreviated BSP). In both cases the actual flip angles, from the measured AFI maps were used. Results The results from the in vitro measurement are presented in Fig. 1. Obtained water/ERETIC ratios in the VOI are shown without any correction for the localization profile (1B) and with the two corrections proposed in this work (1C, 1D). Fig. 1E shows the difference between the Cho/water and Cho/ERETIC ratios, when ERETIC is corrected with BSP. The coefficient of variation of the ratios over the voxels in the pass band of the regarding RF pulses are 3.3 % for the Cho/water, 4.88 % for Cho/ERETIC with ACP, 4.95 % for Cho/ERETIC with BSP and 8.8 % for Cho/ERETIC without corrections for the localization profile. From the in vivo measurements the calculated Cr/ERETIC ratios with BSP correction are shown and compared with the Cr/water ratios in Fig. 2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ERETIC based in vivo H MRSI quantification

Introduction Quantification of metabolite concentrations from spectroscopic images has been performed by a variety of approaches: Absolute quantification based on internal water referencing [1] is the current method of choice. It accounts for B1 variations across the field of view but imposes problems when assessing diseases that lead to alteration of tissue water concentration [2] and relaxati...

متن کامل

Electronic reference for absolute quantification of brain metabolites by 1H-MRS on clinical whole-body imaging.

BACKGROUND AND PURPOSE The electronic reference to access in vivo concentrations (ERETIC) method is a promising technique for absolute concentration quantification by brain proton magnetic resonance spectroscopy ((1)H-MRS). However, in its usual form, the technique cannot be implemented in most clinical MR scanners. For this reason, we propose a new strategy for transmitting the ERETIC signal b...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Quantification of Fatty Acids in Human Calf Adipose Tissue and Muscle by C MRS using J-refocused PRESS DEPT and ERETIC

Introduction Fatty acids serve as an important source of energy for muscular contraction and general metabolism [1]. Skeletal muscle fatty acid metabolism has been found in association with insulin resistance [2]. Compared to H MRS, which enables distinction of intramyocellular (IMCL) and extramyocellular (EMCL) lipids, in vivo C MRS offers a better separation of saturated and unsaturated fatty...

متن کامل

Evaluation of the ERETIC method as an improved quantitative reference for 1H HR-MAS spectroscopy of prostate tissue.

The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to (1)H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative reference were evaluated in solution and human prostate tissue samples. For comparison, the reliability of 3-(trimethylsilyl)propionic-2,2,3,3-d(4) acid (TSP) as a quantitation reference was also evaluated. The ERET...