Severe Periprosthetic Metallosis and Polyethylene Liner Failure Complicating Total Hip Replacement: The Cloud Sign

نویسندگان

  • Amir Paydar
  • Felix S. Chew
  • Paul A. Manner
چکیده

We present a case of an 85-year-old woman with extensive metallosis of the left hip joint secondary to prosthetic polyethelene liner dislocation and wear. Radiographs demonstrated amorphous cloudy radiodensities surrounding the prosthesis, a feature we have called the "cloud sign." The presence of amorphous cloudy radiodensities as a radiographic sign of metallosis has not been previously described to our knowledge.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe metallosis following oxidised zirconium wear in total hip arthroplasty.

To cite: Gkouliopoulou E, Agathangelidis F, Vampertzis T, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2016218025 DESCRIPTION We present a case of a man aged 81 years who underwent a primary cementless total hip arthroplasty. Eight years after the index surgery, failure of the arthroplasty was revealed by the presence of the radiographic ‘cloud sign’ (fi...

متن کامل

The Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner

BACKGROUND Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and ...

متن کامل

Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty

INTRODUCTION Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied e...

متن کامل

Metallosis and Metal-Induced Synovitis Following Total Knee Arthroplasty: Review of Radiographic and CT Findings.

Metallosis and metal-induced synovitis are well-recognized complications of metal-backed polyethylene joint prostheses and have been frequently described in the orthopedic surgery literature; however, relatively fewer articles discussing the radiologic aspects of this complication have been published. To illustrate the importance of radiologic findings in the diagnosis and management of these p...

متن کامل

Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2007