Accuracy estimation for projection-to-volume targeting during rotational therapy: A feasibility study.
نویسندگان
چکیده
PURPOSE Estimating motion and deformation parameters from a series of projection radiographs acquired during arc therapy using a reference CT volume has become a promising technique for targeting treatment. The purpose of this work is to investigate the influence of rotational arc length on maximum achievable accuracy of motion estimation. METHODS The projection-to-volume alignment procedure used a nonrigid model to describe motion in thorax area, a cost function consisting of a least-squared error metric and a simple regularizer that encourages local invertibility, and a four-level multiresolution scheme with a conjugate gradient method to optimize the cost function. The authors tested both small and large scale deformations typically found in the thorax of a radiotherapy patient at different breathing states and limited-angle scans of six angular widths (12°, 18°, 24°, 36°, 60°, and 90°) centered at three angles (0°, 45°, and 90°). RESULTS The experiments illustrate the potential accuracy of limited-angle projection-to-volume alignment. Registration accuracy can be sensitive to angular center, tends to be lower along direction of the projection set, and tends to decrease away from the rotation center. The studies of small as well as large but realistically scaled deformations show similar dependencies. These trends appear to have fairly low sensitivity to quantum noise effects. CONCLUSIONS There is potentially sufficient information present in a small spread of projections to monitor the configuration of reasonably high contrast tumors without implanted markers.
منابع مشابه
Statistical Image Reconstruction and Motion Estimation for Image-Guided Radiotherapy
Statistical Image Reconstruction and Motion Estimation for Image-Guided Radiotherapy by Yong Long Co-Chairs: Jeffrey A. Fessler and James M. Balter Image reconstruction and motion estimation are very important for image-guided radiotherapy (IGRT). Three-dimensional reconstruction of patient anatomy using X-ray computed tomography (CT) allows identification of the location of a tumor prior to tr...
متن کاملA feasibility study on the use of MV-CBCT images for urgent palliative treatment planning
Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...
متن کاملانجام یک مرحله پیش پردازش قبل از مرحله استخراج ویژگی در طبقه بندی داده های تصاویر ابر طیفی
Hyperspectral data potentially contain more information than multispectral data because of their higher spectral resolution. However, the stochastic data analysis approaches that have been successfully applied to multispectral data are not as effective for hyperspectral data as well. Various investigations indicate that the key problem that causes poor performance in the stochastic approaches t...
متن کاملFeasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom
Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....
متن کاملEstimation of the risk for the second cancers induction in healthy tissues during the radiation therapy of liver’s tumor
The aim of this study was to estimate the delivered doses to tissues and organs around the liver tumor during radiotherapy and to determine organs with a high probability of secondary induction cancers. This study was carried out using Monte Carlo method. The used Phantom, the ORNL phantom is for an adult female. The volume of the tumor is as much as 30% of the liver tissue.In the initial step...