The 400 microsphere per piece "rule" does not apply to all blood flow studies.

نویسندگان

  • N L Polissar
  • D C Stanford
  • R W Glenny
چکیده

Microsphere experiments are useful in measuring regional organ perfusion as well as heterogeneity of blood flow within organs and correlation of perfusion between organ pieces at different time points. A 400 microspheres/piece "rule" is often used in planning experiments or to determine whether experiments are valid. This rule is based on the statement that 400 microspheres must lodge in a region for 95% confidence that the observed flow in the region is within 10% of the true flow. The 400 microspheres precision rule, however, only applies to measurements of perfusion to a single region or organ piece. Examples, simulations, and an animal experiment were carried out to show that good precision for measurements of heterogeneity and correlation can be obtained from many experiments with <400 microspheres/piece. Furthermore, methods were developed and tested for correcting the observed heterogeneity and correlation to remove the Poisson "noise" due to discrete microsphere measurements. The animal experiment shows adjusted values of heterogeneity and correlation that are in close agreement for measurements made with many or few microspheres/piece. Simulations demonstrate that the adjusted values are accurate for a variety of experiments with far fewer than 400 microspheres/piece. Thus the 400 microspheres rule does not apply to many experiments. A "rule of thumb" is that experiments with a total of at least 15,000 microspheres, for all pieces combined, are very likely to yield accurate estimates of heterogeneity. Experiments with a total of at least 25,000 microspheres are very likely to yield accurate estimates of correlation coefficients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of infarcted myocardium on regional blood flow measurements to ischemic regions in canine heart.

The present study assesses effects of acutely infarcted myocardium on apparent microsphere loss as a function of time, determines effects of apparent microsphere loss on blood flow measurements to ischemic regions, and determines to what extent apparent microsphere loss alters interpretation of serial measurements of collateral blood flow. Studies were performed in 35 awake mongrel dogs chronic...

متن کامل

Validation of fluorescent-labeled microspheres for measurement of relative blood flow in severely injured lungs.

The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microsph...

متن کامل

Spatial pattern of pulmonary blood flow distribution is stable over days.

Despite the heterogeneous distribution of regional pulmonary perfusion over space, local perfusion remains stable over short time periods (20-100 min). The purpose of this study was to determine whether the spatial distribution of pulmonary perfusion remains stable over longer time periods (1-5 days). Regional blood flow was measured each day for 5 days in five awake standing dogs. Fluorescent ...

متن کامل

Microsphere maps of regional blood flow and regional ventilation.

Systematically mapped samples cut from lungs previously labeled with intravascular and aerosol microspheres can be used to create high-resolution maps of regional perfusion and regional ventilation. With multiple radioactive or fluorescent microsphere labels available, this methodology can compare regional flow responses to different interventions without partial volume effects or registration ...

متن کامل

Blood flow and distribution in the canine pancreas.

Because of a tripartite arterial inflow, accurate determination of canine pancreatic blood flow (QP) in experimental studies remains problematic. Assessment of blood flow using a single electromagnetic flow probe on the anterior pancreaticoduodenal artery (APDA) was compared to the radiolabeled microsphere method. Distribution of QP was based on microsphere density. QP determined simultaneously...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 278 1  شماره 

صفحات  -

تاریخ انتشار 2000