Measurement of Neutron Flux in a Medical Compact cyclotron room with Boron-Containing water Self-Shielding

نویسندگان

  • Toshioh Fujibuchi
  • Genki Horitsugi
  • Ichiro Yamaguchi
  • Akihisa Eto
  • Yasuo Iwamoto
  • Satoshi Obara
  • Hiroshi Watanabe
  • Jun Hatazawa
چکیده

a) Department of Radiological Sciences, School of Health Sciences, Ibaraki Prefectural University of Health Sciences, Ami 4669-2, Ami-machi, Inashiki-gun, Ibaraki 300-0394, Japan b) MI clinic, Syouji 1-12-13, Toyonaka City, Osaka 560-0004, Japan c) National Institute of Public Health, Minami 2-3-6, Wako City, Saitama 351-0197, Japan d) Yokohama Rousai Hospital, Kodzukue-cho 3211, Kofuku-ku, Yokohama City, Kanagawa 222-0036, Japan e) Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, Yamada Oka 2-2, Suita City, Osaka 565-0871, Japan

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiologic assessment of a self-shield with boron-containing water for a compact medical cyclotron

The cyclotron at our hospital has a self-shield of boron-containing water. The amount of induced radioactivity in the boron-containing water shield of a compact medical cyclotron has not yet been reported. In this study, we measured the photon and neutron dose rates outside the self-shield during cyclotron operation. We estimated the induced radioactivities of the boron-containing water used fo...

متن کامل

Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit

For passive scattering proton therapy systems, neutron contamination is the main concern both from an occupational and patient safety perspective. The Mevion S250 compact proton therapy system is the first of its kind, offering an in-room cyclotron design which prompts more concern for shielding assessment. The purpose of this study was to accomplish an in-depth evaluation of both the shielding...

متن کامل

Investigation of Developed Shield Composition to Neutron Shielding in Treatment Room for BNCT to Reduce Clinical Effects

Background and Aim: One of the best radiotherapy methods that have been suggested for the treatment of cancers such as brain, head and neck, skin, and recently liver is boron neutron capture therapy. Therefore, neutron shielding in the treatment room is important because the absorption of neutrons in the shield may lead to the production of gamma rays, which can have destructive effects. While ...

متن کامل

Using Zirconium Borohydride as Neutron Shield in LINAC head

Introduction: One of the concerns about using of high energy photons in radiotherapy is neutron contamination production. The threshold energy of photoneutron production in most materials with high atomic number is about 7MeV. Therefore, it seems to be logical that the main components with high atomic number elements used in the LINAC head have a large contribution to the neutr...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015