An optimized fast protocol for magnetic resonance imaging of the temporomandibular joint.
نویسندگان
چکیده
OBJECTIVES To provide a fast protocol for MR imaging of the TMJ with high contrast resolution of both soft tissue and joint fluid. METHODS A fast turbo-spin echo (TSE) pulse sequence was developed. The new technique was compared with T1W conventional spin echo (CSE) and T2W TSE sequences in imaging 57 TMJs in 50 patients. Disc location and contour and bone delineation were assessed on three images of each TMJ by one observer. Presence and location of intra-articular fluid were evaluated on both standard T2W and new TSE images. Image quality was scored on a 3 point-scale by one observer. RESULTS The net image acquisition time for one plane was 2 min with the new TSE sequence compared with approximately 5-10 min for T1W and 4 min for T2W. The new sequence provided equivalent diagnostic information to a combination of T1W CSE for disc position and contour and bone contour and T2W TSE sequence for joint fluid. CONCLUSIONS The examination time for MRI of the TMJ can be considerably reduced with the new fast TSE pulse sequence without compromising image quality.
منابع مشابه
بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافتههای Magnetic Resonance Imaging
Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...
متن کاملAccuracy Rate of Clinical Diagnosis of Disc Displacement without Reduction in Temporomandibular Joint Using MRI
Introduction: Internal derangement (ID) of TMJ is the most common type of temporomandibular disorders after muscle disorders and includes all disorders related to incoordination and dislocation of disc and condyle. Anterior disc displacement without reduction or closed lock will happen if the disc or condyle displaces severely or if the disc traps in the space in front of the condyle accompanie...
متن کاملUse of Magnetic Resonance Imaging in Food Quality Control: A Review
Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...
متن کاملMagnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach
Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...
متن کاملMagnetic resonance imaging parameter optimizations for diagnosis of periprosthetic infection and tumor recurrence in artificial joint replacement patients
To evaluate the efficacy of magnetic resonance imaging (MRI) parameter optimizations for the diagnosis of periprosthetic infection and tumor recurrence in joint replacement patients. We compared the quality of images for 16 joint replacement patients that were recorded using the optimized MRI parameters with and without view angle tilting (VAT) correction at 1.5 T in coronal fast-spin-echo T2-w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Dento maxillo facial radiology
دوره 30 2 شماره
صفحات -
تاریخ انتشار 2001