Variability in Dengue Titer Estimates from Plaque Reduction Neutralization Tests Poses a Challenge to Epidemiological Studies and Vaccine Development
نویسندگان
چکیده
BACKGROUND Accurate determination of neutralization antibody titers supports epidemiological studies of dengue virus transmission and vaccine trials. Neutralization titers measured using the plaque reduction neutralization test (PRNT) are believed to provide a key measure of immunity to dengue viruses, however, the assay's variability is poorly understood, making it difficult to interpret the significance of any assay reading. In addition there is limited standardization of the neutralization evaluation point or statistical model used to estimate titers across laboratories, with little understanding of the optimum approach. METHODOLOGY/PRINCIPAL FINDINGS We used repeated assays on the same two pools of serum using five different viruses (2,319 assays) to characterize the variability in the technique under identical experimental conditions. We also assessed the performance of multiple statistical models to interpolate continuous values of neutralization titer from discrete measurements from serial dilutions. We found that the variance in plaque reductions for individual dilutions was 0.016, equivalent to a 95% confidence interval of 0.45-0.95 for an observed plaque reduction of 0.7. We identified PRNT75 as the optimum evaluation point with a variance of 0.025 (log10 scale), indicating a titer reading of 1∶500 had 95% confidence intervals of 1∶240-1∶1000 (2.70±0.31 on a log10 scale). The choice of statistical model was not important for the calculation of relative titers, however, cloglog regression out-performed alternatives where absolute titers are of interest. Finally, we estimated that only 0.7% of assays would falsely detect a four-fold difference in titers between acute and convalescent sera where no true difference exists. CONCLUSIONS Estimating and reporting assay uncertainty will aid the interpretation of individual titers. Laboratories should perform a small number of repeat assays to generate their own variability estimates. These could be used to calculate confidence intervals for all reported titers and allow benchmarking of assay performance.
منابع مشابه
Description of a Prospective 17DD Yellow Fever Vaccine Cohort in Recife, Brazil
From September 2005 to March 2007, 238 individuals being vaccinated for the first time with the yellow fever (YF) -17DD vaccine were enrolled in a cohort established in Recife, Brazil. A prospective study indicated that, after immunization, anti-YF immunoglobulin M (IgM) and anti-YF IgG were present in 70.6% (IgM) and 98.3% (IgG) of the vaccinated subjects. All vaccinees developed protective im...
متن کاملCharacterization of antibody responses to combinations of a dengue virus type 2 DNA vaccine and two dengue virus type 2 protein vaccines in rhesus macaques.
We evaluated three nonreplicating dengue virus type 2 (DENV-2) vaccines: (i) a DNA vaccine containing the prM-E gene region (D), (ii) a recombinant subunit protein vaccine containing the B domain (i.e., domain III) of the E protein as a fusion with the Escherichia coli maltose-binding protein (R), and (iii) a purified inactivated virus vaccine (P). Groups of four rhesus macaques each were prime...
متن کاملShort report: Antibody responses of mice immunized with a tetravalent dengue recombinant protein subunit vaccine.
Recombinant proteins containing the B domain of dengue virus serotypes 1-4 fused to the maltose binding protein (MBP) of Escherichia coli were evaluated individually and as a tetravalent vaccine candidate in mice. Sera from mice immunized with monovalent DEN-MBP recombinant protein vaccines developed high titers of serotype homologous antibody in the enzyme-linked immunosorbent assay and the pl...
متن کاملVariation in dengue virus plaque reduction neutralization testing: systematic review and pooled analysis
BACKGROUND The plaque reduction neutralization test (PRNT) remains the gold standard for the detection of serologic immune responses to dengue virus (DENV). While the basic concept of the PRNT remains constant, this test has evolved in multiple laboratories, introducing variation in materials and methods. Despite the importance of laboratory-to-laboratory comparability in DENV vaccine developme...
متن کاملOptimization and Validation of a Plaque Reduction Neutralization Test for the Detection of Neutralizing Antibodies to Four Serotypes of Dengue Virus Used in Support of Dengue Vaccine Development
A dengue plaque reduction neutralization test (PRNT) to measure dengue serotype-specific neutralizing antibodies for all four virus serotypes was developed, optimized, and validated in accordance with guidelines for validation of bioanalytical test methods using human serum samples from dengue-infected persons and persons receiving a dengue vaccine candidate. Production and characterization of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2014