Comparison of direct laryngoscopy to Pediatric King LT-D in simulated airways.
نویسندگان
چکیده
OBJECTIVES Previous reports have shown a high rate of ventilation failure via direct laryngoscopy as compared with the King LT-D airway. This difference is further divergent in the pediatric population. The goal of this study was to compare the difference in efficacy of ventilation by prehospital providers in a simulated environment between direct laryngoscopy and Pedi-King LT-D. METHODS In this study, 37 paramedics were exposed to 2 identical 5-minute clinical scenarios in a simulation center using a pediatric simulation tool. In the first scenario, the provider was given all of the standard laryngoscopy equipment. In the second scenario, they were given access only to the Pedi-King LT-D. A comparison of adequate ventilation time between the scenarios was performed. RESULTS A mean improvement of 102 seconds was found when using the Pedi-King airway, with a clinically significant P < 0.0001. CONCLUSIONS With a significant improvement in ventilation time in these simulated airways, consideration should be made to practice placement of the King Airway Device as first-line airway stabilization. Further live prospective studies would aid in this recommendation.
منابع مشابه
Assessment of the storz video Macintosh laryngoscope for use in difficult airways: A human simulator study.
OBJECTIVES Video laryngoscopy has been shown to improve glottic exposure when compared to direct laryngoscopy in operating room studies. However, its utility in the hands of emergency physicians (EPs) remains undefined. A simulated difficult airway was used to determine if intubation by EPs using a video Macintosh system resulted in an improved glottic view, was easier, was faster, or was more ...
متن کاملComparison of hemodynamic changes in patients using conventional laryngoscopy and video laryngoscope in surgery
Introduction: One of the complications of laryngoscopy and endotracheal intubation is sympathetic stimulation with hemodynamic changes that are always tried to be avoided by anesthesiologists. The aim of this study is to review and compare hemodynamic changes caused by both conventional and video laryngoscopy. Methods: In this clinical trial performed in 2015 in the Birjand-based Imam Reza Hosp...
متن کاملImproved success rates using videolaryngoscopy in unexperienced users: a randomized crossover study in airway manikins
BACKGROUND Videolaryngoscopy has been proven to be a safe procedure managing difficult airways in the hands of airway specialists. Information about the success rates in unexperienced users of videolaryngoscopy compared to conventional laryngoscopy is sparse. Therefore, we aimed to evaluate if there might be more success in securing an airway if the unexperienced provider is using a videolaryng...
متن کاملComparison of Master's Degree Curriculum for Pediatric Nursing in Iran and King of England: A Comparative Study
Introduction: Comparing curriculum with each other will identify the strengths and weaknesses of the program and provide a framework for revising and updating educational programs. Since the purpose of the pediatric nursing program is to provide, maintain and promote the health of the child and the family; therefore, the purpose of this study was to compare the Master's degree curriculum for Pe...
متن کاملComparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways.
OBJECTIVE Recently, to further enhance the potential in the management of difficult airways, the highly angulated D-Blade was added to the C-MAC system. The purpose of this study was to investigate the laryngoscopic view and intubation parameters using the new C-MAC D-Blade in comparison to the conventional C-MAC video laryngoscope and Macintosh direct laryngoscope in simulated easy and difficu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pediatric emergency care
دوره 28 8 شماره
صفحات -
تاریخ انتشار 2012