Premature ventricular contraction detection using swarm-based support vector machine and QRS wave features

نویسندگان

  • Nuryani Nuryani
  • Iwan Yahya
  • Anik Lestari
چکیده

A novel strategy for detecting Premature Ventricular Contraction (PVC) is proposed and investigated. The strategy employs a Swarm-based Support Vector Machine (SSVM). An SSVM is an SVM optimised by using Particle Swarm Optimisation (PSO). The strategy proposes new inputs. The inputs involve the width and the gradient of the electrocardiographic QRS wave. Experiments with different inputs and different SVM kernel functions are conducted to find the best one for PVC detection. On a test using clinical data, SSVM performs well in PVC detection with sensitivity, specificity and accuracy of 98.94%, 99.99% and 99.46%, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection and Classification of Heart Premature Contractions via α-Level Binary Neyman-Pearson Radius Test: A Comparative Study

The aim of this study is to introduce a new methodology for isolation of ectopic rhythms of ambulatory electrocardiogram (ECG) holter data via appropriate statistical analyses imposing reasonable computational burden. First, the events of the ECG signal are detected and delineated using a robust wavelet-based algorithm. Then, using Binary Neyman-Pearson Radius test, an appropriate classifie...

متن کامل

Detection of Cardiac Hypertrophy by RVM and SVM Algorithms

The meaning of the hypertropy word is the increasing size.Heart hypertropy is symptoms of increase the thickness of the heart muscle that the left ventricular hypertrophy of them is the most common.The causes of hypertrophy heart disease are high blood pressure , aortic valve stenosis and sport activities respectively. Assessment of that by using ECG signal analysis is essential Because the ris...

متن کامل

Automated Diagnosis of Cardiac Health

Electrocardiogram (ECG) is the P, QRS, T wave representing the electrical movement of the heart. The fine changes in amplitude and interval of ECG cannot be interpreted exactly by the naked eye, hence imposing the need for a computer assisted diagnosis tool. Automatically classified five types of ECG beats of MIT-BIH arrhythmia records. The five types of beats are Normal (N), Right Bundle Branc...

متن کامل

Comparison of Parametric and Non-parametric EEG Feature Extraction Methods in Detection of Pediatric Migraine without Aura

Background: Migraine headache without aura is the most common type of migraine especially among pediatric patients. It has always been a great challenge of migraine diagnosis using quantitative electroencephalography measurements through feature classification. It has been proven that different feature extraction and classification methods vary in terms of performance regarding detection and di...

متن کامل

A Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure

In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014