Registration between ultrasound and fluoroscopy or CT in prostate brachytherapy.

نویسندگان

  • P Fallavollita
  • Z Karim Aghaloo
  • E C Burdette
  • D Y Song
  • P Abolmaesumi
  • G Fichtinger
چکیده

PURPOSE In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be visualized by fluoroscopy. Intraoperative dosimetry optimization is possible using a combination of TRUS and fluoroscopy, but requires localization of the fluoroscopy-derived seed cloud, relative to the anatomy as seen on TRUS. The authors propose to develop a method of registration of TRUS images and the implants reconstructed from fluoroscopy. METHODS A phantom was implanted with 48 seeds then imaged with TRUS and CT. Seeds were reconstructed from CT yielding a cloud of seeds. Fiducial-based ground-truth registration was established between the TRUS and CT. TRUS images are filtered, compounded, and registered to the reconstructed implants by using an intensity-based metric. The authors evaluated a volume-to-volume and point-to-volume registration scheme. In total, seven TRUS filtering techniques and three image similarity metrics were analyzed. The method was also tested on human subject data captured from a brachytherapy procedure. RESULTS For volume-to-volume registration, noise reduction filter and normalized correlation metrics yielded the best result: An average of 0.54 +/- 0.11 mm seed localization error relative to ground truth. For point-to-volume registration, noise reduction combined with beam profile filter and mean squares metrics yielded the best result: An average of 0.38 +/- 0.19 mm seed localization error relative to the ground truth. In human patient data, C-arm fluoroscopy images showed 81 radioactive seeds implanted inside the prostate. A qualitative analysis showed clinically correct agreement between the seeds visible in TRUS and reconstructed from intraoperative fluoroscopy imaging. The measured registration error compared to the manually selected seed locations by the clinician was 2.86 +/- 1.26 mm. CONCLUSIONS Fully automated registration between TRUS and the reconstructed seeds performed well in ground-truth phantom experiments and qualitative observation showed adequate performance on early clinical patient data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localization of Brachytherapy Seeds in Ultrasound by Registration to Fluoroscopy

Motivation: In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be seen in C-arm fluoroscopy or CT. Intra-operative dosimetry optimization requires localization of the implants in TRUS relative to the anatomy. This could be achieved by registration of TRUS images and the implants reconstructed from fluoroscopy or CT. Methods: TRUS...

متن کامل

C-arm Pose Estimation in Prostate Brachytherapy by Registration to Ultrasound

In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be seen in C-arm fluoroscopy. Intra-operative dosimetry optimization requires reconstruction of the implanted seeds from multiple C-arm fluoroscopy images, which in turn requires estimation of the C-arm poses. We estimate the pose of the C-arm by two-stage registration between th...

متن کامل

Towards Intra-operative Prostate Brachytherapy Dosimetry Based on Partial Seed Localization in Ultrasound and Registration to C-arm Fluoroscopy

Intraoperative dosimetry during prostate brachytherapy is a long standing clinical problem. We propose a novel framework to address this problem by reliable detection of a subset of seeds from 3D transrectal ultrasound and registration to fluoroscopy. Seed detection in ultrasound is achieved through template matching in the RF ultrasound domain followed by thresholding and spatial filtering bas...

متن کامل

Intra-operative Localization of Brachytherapy Implants Using Intensity-based Registration.

In prostate brachytherapy, a transrectal ultrasound (TRUS) will show the prostate boundary but not all the implanted seeds, while fluoroscopy will show all the seeds clearly but not the boundary. We propose an intensity-based registration between TRUS images and the implant reconstructed from uoroscopy as a means of achieving accurate intra-operative dosimetry. The TRUS images are first filtere...

متن کامل

Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry

Prostate brachytherapy is a treatment for prostate cancer using radioactive seeds that are permanently implanted in the prostate. The treatment success depends on adequate coverage of the target gland with a therapeutic dose, while sparing the surrounding tissue. Since seed implantation is performed under transrectal ultrasound (TRUS) imaging, intraoperative localization of the seeds in ultraso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 6Part1  شماره 

صفحات  -

تاریخ انتشار 2010