Novel grey model for the prediction of trend of dissolved gases in oil-filled power apparatus

نویسنده

  • M. H. Wang
چکیده

The power transformer is a major apparatus in a power system; it is of great importance to detect incipient failures in power transformers as early as possible in order to minimize system outage. In this paper, the modified grey model was applied to predict the oil-dissolved gas trend of power transformers. Then, the future fault of power transformer can directly be identified by the trend analysis, so that we can switch them off safely and improve the reliability of power systems. To verify the proposed approach, 46 sets of power transformer records in Taiwan have been tested. It is shown that the proposed method is simple and efficient. # 2003 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Grey Prediction Model for Forecasting Electricity consumption

Accurate prediction of the future electricity consumption is crucial for production electricity management. Since the storage of electrical energy is very difficult, reliable and accurate prediction of power consumption is important. Different approaches for this purpose were used. In this paper, Grey model (1,1) based on grey system theory has been used for forecasting results. Annual electric...

متن کامل

Application of Grey System Theory in Rainfall Estimation

Considering the fact that Iran is situated in an arid and semi-arid region, rainfall prediction for the management of water resources is very important and necessary. Researchers have proposed various prediction methods that have been utilized in such areas as water and meteorology, especially water resources management. The present study aimed at predicting rainfall amounts using Grey Predicti...

متن کامل

Prediction of the Characteristics of Transformer Oil under Different Operation Conditions

Power systems and transformer are intrinsic apparatus, therefore its reliability and safe operation is important to determine their operation conditions, and the industry uses quality control tests in the insulation design of oil filled transformers. Hence the service period effect on AC dielectric strength is significant. The effect of aging on transformer oil physical, chemical and electrical...

متن کامل

Grey prediction in linear programming problems

The purpose of this paper is describes the use of grey pridiction in linear programming problems. Some definitions and concepts of grey system theory are introduced and then, we introduced GM(1,1) and fractional order accumulation into grey model. Due to the fluctuation of prices and the lack of certainty data in the market, optimal production was calculated to optimize the profit from sales us...

متن کامل

Fuzzy-Logic Applications in Transformer Diagnosis Using Individual and Total Dissolved Key Gas Concentrations

The gases generated in oil filled transformer can be used for determination of incipient faults. Dissolved gas analysis (DGA) of transformer oil has been one of the most power full methods to detect the faults. The various methods such as liquid chromatography, acoustic analysis, and transformer function techniques are require some experience to interpret observations. The researchers have used...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003