Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa.

نویسندگان

  • R Williams
  • N Rankin
  • T Smith
  • D Galler
  • P Seakins
چکیده

OBJECTIVE To review the available literature on the relationship between the humidity and temperature of inspired gas and airway mucosal function. DATA SOURCES International computerized databases and published indices, experts in the field, conference proceedings, bibliographies. STUDY SELECTION/DATA EXTRACTION Two hundred articles/texts on respiratory tract physiology and humidification were reviewed. Seventeen articles were selected from 40 articles for inclusion in the published data verification of the model. Selection was by independent reviewers. Extraction was by consensus, and was based on finding sufficient data. DATA SYNTHESIS A relationship exists between inspired gas humidity and temperature, exposure time to a given humidity level, and mucosal function. This relationship can be modeled and represented as an inspired humidity magnitude vs. exposure time map. The model is predictive of mucosal function and can be partially verified by the available literature. It predicts that if inspired humidity deviates from an optimal level, a progressive mucosal dysfunction begins. The greater the humidity deviation, the faster the mucosal dysfunction progresses. CONCLUSIONS A model for the relationship between airway mucosal dysfunction and the combination of the humidity of inspired gas and the duration over which the airway mucosa is exposed to that humidity is proposed. This model suggests that there is an optimal temperature and humidity above which, and below which, there is impaired mucosal function. This optimal level of temperature and humidity is core temperature and 100% relative humidity. However, existing data are only sufficient to test this model for gas conditions below core temperature and 100% relative humidity. These data concur with the model in that region. No studies have yet looked at this relationship beyond 24 hrs. Longer exposure times to any given level of inspired humidity and inspired gas temperatures and humidities above core temperature and 100% relative humidity need to be studied to fully verify the proposed model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring of dust phenomenon and Investigate its correlation with temperature and humidity parameters‌ (Case study: Khuzestan Province)

Dust is a phenomenon in arid and semi-arid areas due to high wind speeds on the un-polluted soil surface and prone to erosion. The occurrence of dust has always been a problem for residents in the western and southwestern regions of the country, has gradually spread to other provinces, including the capital. The study area is southwest of Iran, Khuzestan province. The latitude and longitude of ...

متن کامل

The study of humidity effect on carbon dioxide gas sensing properties of zinc oxide nanowires assisted by polyvinyl alcohol network at room temperature

In this research, Zinc oxide (ZnO) nanostructures were synthesized by low cost hydrothermal method. The grown ZnO nanostructures had a dispersed distribution with nanowire morphology and the specific surface area of about 7 m2.gr-1 which they have crystalized in hexagonal wurtzite structure. ZnO nanowires/polyvinyl alcohol network (ZP) on the epoxy glass substrate with cu-interdigited electrods...

متن کامل

Medical Meteorology;the Relationship between Meteorological Parameters (Humidity, Rainfall, Wind, and Temperature) and Brucellosis in Zanjan Province

Background: Brucellosis (Malta fever) is a major contagious zoonotic disease, with economic and public health importance. Methods: To assess the effect of meteorological (temperature, rainfall, humidity, and wind) and climate parameters on incidence of brucellosis, brucellosis distribution and meteorological zoning maps of Zanjan Province were prepared using Inverse Distance Weighting (IDW) an...

متن کامل

Relationship between venous blood gas parameters, thyroid hormone levels and ascites syndrome in broiler chickens exposed to cold temperature

The objective of this study was to find a relationship between blood gas parameters and thyroid hormoneactivity with ascites syndrome in broiler chickens exposed to cold temperature and receiving a high qualitydiet. One hundred and sixty one-day-old broiler chicks were randomly divided in two equal groups. Toincrease the incidence of ascites, chicks of group 1 were fed ad libitum with a higher ...

متن کامل

Modeling and Optimization of non - isothermal two- phase flow in the cathode gas diffusion layer of PEM fuel cell

In this paper, a non-isothermal two-phase flow in the cathode gas diffusion layer (GDL) of PEM fuel cell is modeled. The governing equations including energy, mass and momentum conservation equations are solved by numerical methods. Also, the optimal values of the effective parameters such as the electrodes porosity, gas diffusion layer (GDL) thickness and inlet relative humidity are calculated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 24 11  شماره 

صفحات  -

تاریخ انتشار 1996