The New Method on Detection Singularity of Harmonics in Power System
نویسندگان
چکیده
This paper introduces a new method which can detect singularity of harmonics in power system, and combining the wavelet transform with Fourier transform to give full play their advantages, commonly detect and analyse the harmonic in power system . Firstly, using the wavelet transform to analyze the high frequency components of the signals, and determine the signal catastrophe point and occurring time and amplitude of high frequency harmonic oscillation, then analyze the low frequency component by FFT , and require the harmonics parameters. This paper gives the harmonic detection scheme which combines wavelet transform and FFT, and simulation and analysis the harmonic wave with the singular point in power system. The simulation result is satisfied and it is validated that the proposed method has the good analytical capability of unstable signals.
منابع مشابه
Power filtering method with controllable inductance for eliminating thyristor rectifier load harmonics
In this paper, we propose a Controlled Inductance Power Filter (CIPF) to solve power quality problems in industrial DC power supply systems. This method is based on the theory of magnetic potential equilibrium combined with active hybrid filter technology. Initially the system structure and filter wiring scheme are presented and the equivalent circuit is performed with the mathematical models o...
متن کاملA New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)
This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...
متن کاملNew Methods for Harmonic Reduction in T. C. R. by Sequence Control of Transformer Taps
Thyristor controlled static compensators consist of two basic schemes, TCR and TSC. Owing to the discontinuous current in TCR, current harmonics are generated in the supply system. This paper introduces two methods for the reduction of these harmonics. On the basis of the coordination or uncoordination of turn ratios with harmonic reduction levels, each method is described in two alternative sc...
متن کاملA New Analog-based LO Harmonic Rejection Technique with Tunable Notch Frequency
An effective technique for mixer LO harmonic rejection in a SAW-less wideband receiver front-end is proposed. The proposed technique provides a tunable notch that can be placed at any frequency like mixer LO harmonics, to avoid the aliasing in baseband after mixing. An analog LC notch is used in a cascode transconductor, and it can reject one of the 3rd or 5th harmonics. T...
متن کاملA New Control for Series Compensation of UPQC to Improve Voltage Sag/Swell
Voltage sag/swell is one of the most frequently power quality problems which affects the power systems with sensitive loads. The unified power quality conditioner (UPQC) is capable of mitigating the effect of voltage sag/swell at the load or point of common coupling (PCC). In this paper, a new control of UPQC is proposed based on combining the sag detection and voltage injection established on ...