Scaling-up of a novel, simplified MFC stack based on a self-stratifying urine column.
نویسندگان
چکیده
BACKGROUND The microbial fuel cell (MFC) is a technology in which microorganisms employ an electrode (anode) as a solid electron acceptor for anaerobic respiration. This results in direct transformation of chemical energy into electrical energy, which in essence, renders organic wastewater into fuel. Amongst the various types of organic waste, urine is particularly interesting since it is the source of 75 % of the nitrogen present in domestic wastewater despite only accounting for 1 % of the total volume. However, there is a persistent problem for efficient MFC scale-up, since the higher the surface area of electrode to volume ratio, the higher the volumetric power density. Hence, to reach usable power levels for practical applications, a plurality of MFC units could be connected together to produce higher voltage and current outputs; this can be done by combinations of series/parallel connections implemented both horizontally and vertically as a stack. This plurality implies that the units have a simple design for the whole system to be cost-effective. The goal of this work was to address the built configuration of these multiple MFCs into stacks used for treating human urine. RESULTS We report a novel, membraneless stack design using ceramic plates, with fully submerged anodes and partially submerged cathodes in the same urine solution. The cathodes covered the top of each ceramic plate whilst the anodes, were on the lower half of each plate, and this would constitute a module. The MFC elements within each module (anode, ceramic, and cathode) were connected in parallel, and the different modules connected in series. This allowed for the self-stratification of the collective environment (urine column) under the natural activity of the microbial consortia thriving in the system. Two different module sizes were investigated, where one module (or box) had a footprint of 900 mL and a larger module (or box) had a footprint of 5000 mL. This scaling-up increased power but did not negatively affect power density (≈12 W/m(3)), a factor that has proven to be an obstacle in previous studies. CONCLUSION The scaling-up approach, with limited power-density losses, was achieved by maintaining a plurality of microenvironments within the module, and resulted in a simple and robust system fuelled by urine. This scaling-up approach, within the tested range, was successful in converting chemical energy in urine into electricity.
منابع مشابه
A new 2D block ordering system for wavelet-based multi-resolution up-scaling
A complete and accurate analysis of the complex spatial structure of heterogeneous hydrocarbon reservoirs requires detailed geological models, i.e. fine resolution models. Due to the high computational cost of simulating such models, single resolution up-scaling techniques are commonly used to reduce the volume of the simulated models at the expense of losing the precision. Several multi-scale ...
متن کاملA Novel Approach to Determine Dosage in Treatment of AIDS Based on Direct Self Tuning Regulator (STR) Theory and Linearization Around Equilibrium Condition
in this study, a new approach for control (treatment) of AIDS based on patient entry drug. One of the main problems related to AIDS, is lack of control, lack of identification and early treatment of this disease. Today physicians more than anything, control the disease relying on their experience and knowledge and time-consuming and complex experiments, nevertheless, human errors are inevitable...
متن کاملProcessing a multifold ground penetration radar data using common-diffraction-surface stack method
Recently, the non-destructive methods have become of interest to the scientists in various fields. One of these method is Ground Penetration Radar (GPR), which can provide a valuable information from underground structures in a friendly environment and cost-effective way. To increase the signal-to-noise (S/N) ratio of the GPR data, multi-fold acquisition is performed, and the Common-Mid-Points ...
متن کاملConceptual design of a super-critical CO2 brayton cycle based on stack waste heat recovery for shazand power plant in Iran
Conceptual design of a waste heat recovery cycle is carried out in attempt to enhance the thermal efficiency of a steam power plant. In the recovery system, super-critical an CO2 is employed as the working fluid operating in a Brayton cycle. Low grade heat rejected by the flue gases through the stack is used as the primary heat source, while a secondary heat exchanger utilizes th...
متن کاملInvestigating the effects of fluidic connection between microbial fuel cells.
Microbial fuel cells (MFCs) can 'treat' wastewater but individually are thermodynamically restricted. Scale-up might, therefore, require a plurality of units operating in a stack which could introduce losses simply through fluidic connections. Experiments were performed on two hydraulically joined MFCs (20 cm apart) where feedstock flowed first through the upstream unit (MFC(up)) and into the d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biotechnology for biofuels
دوره 9 شماره
صفحات -
تاریخ انتشار 2016