Formation of an organic coat and release of corrosion microparticles from metallic magnesium implants

نویسندگان

  • Muhammad Badar
  • Heinrich Lünsdorf
  • Florian Evertz
  • Muhammad Imran Rahim
  • Birgit Glasmacher
  • Hansjörg Hauser
  • Peter P. Mueller
چکیده

Magnesium alloys have been proposed as prospective degradable implant materials. To elucidate the complex interactions between the corroding implants and the tissue magnesium implants were analyzed in a mouse model and the response was compared to that induced by Ti and by the resorbable polymer polyglactin, respectively. One month after implantation distinct traces of corrosion were apparent but the magnesium implants were still intact, whereas resorbable polymeric wound suture implants were already fragmented. Analysis of magnesium implants two weeks after implantation by Energy-Dispersive X-ray spectroscopy (EDX) indicated that magnesium, oxygen, calcium and phosphate were present at the implant surface. One month after implantation the element composition of the outermost layer of the implant was indicative of tissue without detectable levels of magnesium, indicating a protective barrier function of this organic layer. In agreement with this notion, gene expression patterns in the surrounding tissue were highly similar for all implant materials investigated. However, high-resolution imaging using energy filtered transmission electron microscopy (EF-TEM) revealed magnesium-containing microparticles in the tissue in the proximity of the implant. The release of such corrosion particles may contribute to the accumulation of calcium phosphate in the nearby tissue and to bone conductive activities of magnesium implants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Investigation of Polymer Coated Magnesium Incorporated by Mesoporous Silica Nanocontainers

The idea of smart corrosion inhibition is basis on either inhibitor consumption where it is needed or reducing harmful matrix interaction with it. In addition, applying corrosion inhibitor in a coating causes many problems such as loss of inhibition capability, coating degradation, or both. A useful technique to overcome this problem is applying of inert host systems of nanometer dimensions as ...

متن کامل

In vitro Investigation of Polymer Coated Magnesium Incorporated by Mesoporous Silica Nanocontainers

The idea of smart corrosion inhibition is basis on either inhibitor consumption where it is needed or reducing harmful matrix interaction with it. In addition, applying corrosion inhibitor in a coating causes many problems such as loss of inhibition capability, coating degradation, or both. A useful technique to overcome this problem is applying of inert host systems of nanometer dimensions as ...

متن کامل

The Effect of Formulation Type on the Release of Benzoyl Peroxide from Microsponges

      Benzoyl peroxide (BPO) is a first-line topical treatment in acne vulgaris, and it is superior to antibiotics, because the bacteria do not develop resistance to it. Skin irritation is a common side effect, and it has been shown that controlled release of BPO from a delivery system to the skin could reduce the side effects while reducing percutaneous absorption. Therefore, the purpose of t...

متن کامل

Osseoconductive and Corrosion-Inhibiting Plasma-Sprayed Calcium Phosphate Coatings for Metallic Medical Implants

During the last several decades, research into bioceramic coatings for medical implants has emerged as a hot topic among materials scientists and clinical practitioners alike. In particular, today, calcium phosphate-based bioceramic materials are ubiquitously used in clinical applications to coat the stems of metallic endoprosthetic hips as well as the surfaces of dental root implants. Such imp...

متن کامل

طراحی، تهیه و ارزیابی پوشش نوین هیدروکسی آپاتیت-تیتانیوم برای اندوایمپلنت دندانی

Nowadays, application of implants as a new method for replacing extracted teeth have been improved. So, many researches have been performed for improving the characteristics of implants. The aim of this study was to design and produce a desired coating in order to obtaining two goals including improvement of the corrosion behavior of metallic endodontic implant and the bone osseointegration sim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013