Simulating target lesion for endoscopic submucosal dissection training in a live pig model.

نویسندگان

  • M-J Chen
  • C-Y Liu
  • C-J Chen
  • S-C Shih
  • H-Y Wang
چکیده

Endoscopic submucosal dissection (ESD) is a operator-dependent technique for performing en bloc resection of early digestive neoplasms [1]. A panel of experts from Europe reached a consensus that hands-on experience in a model of harvested pig stomach and in live pigs should be a major part of structured training [2]. In the previous training protocol, only a flat target lesion could be considered in the normal mucosa [3]. Then we developed a method of simulating target lesions in ex vivo systems [4], but this still cannot simulate a setting that provides the opportunity to respond to the potential complication of bleeding. This study aimed to evaluate the feasibility of using a simulated target lesion in the stomach of live pig for full ESD training. A pseudopolyp was created in the upper corpus of a pig stomach using a pneumatically activated esophageal variceal ligation device (MD-48709; Sumitoma Corp., Tokyo, Japan) (●" Fig.1a,b). We were able to transect the pseudopolyp with snare cautery (ESG-100, cut 1, power level 100; Olympus Optical Co., Ltd., Tokyo, Japan) (●" Fig.1c), leaving a mucosal defect to simulate a depressed target (●" Fig.1d). The ESDmaneuvers were similar to the standard protocol in human beings. We first used a dual knife (KD650Q; Olympus) to mark the periphery (●" Fig.2a). The target was lifted by submucosal injection (●" Fig.2b). The mucosa outside the markings was initially pre-cut with a dual knife (●" Fig.2c) and then was incised circumferentially (●" Fig.2d) and dissected using a second-generation insulated-tip knife (KD-610L; Olympus). A Coagrasper (FD-410LR; Olympus) was used when visible vessels or active bleeding were identified (●" Fig.2e). The target lesion was then resected (●" Fig.2 f). The most important advantage of the model is that it could enable full ESD training, from how to make proper markings to the delineation of safety margins and the proper management of bleeding.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Feasibility of Using Simulated Targets in the Stomachs of Live Pigs for Full Endoscopic Submucosal Dissection Training

BACKGROUND/AIMS In endoscopic submucosal dissection (ESD) training, only a flat target lesion can usually be simulated in the normal mucosa. This study aimed to evaluate the feasibility of simulated targets in the stomachs of live pigs for complete training. METHODS Six trained endoscopists with hands-on experience with ex vivo, isolated pig stomachs were enrolled in this pilot study. An endo...

متن کامل

A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study

BACKGROUND We developed a novel artificial simulator for endoscopic submucosal dissection (ESD) as a bridge between instructional videos and animal tissue training and aimed to evaluate the feasibility of using an artificial tissue model in ESD training. METHODS Eight gastroenterology fellows from one medical center were enrolled in this ESD training program. Before and after the simulator tr...

متن کامل

Esophageal Endoscopic Submucosal Dissection Assisted by an Overtube with a Traction Forceps: An Animal Study

Esophageal endoscopic submucosal dissection (ESD) is technically difficult. To make it safer, we developed a novel method using overtube with a traction forceps (OTF) for countertraction during submucosal dissection. We conducted an ex vivo animal study and compared the clinical outcomes between OTF-ESD and conventional method (C-ESD). A total of 32 esophageal ESD procedures were performed by f...

متن کامل

SCIENTIFIC LETTERS Endoscopic gastric submucosal dissection in low-grade intraepithelial neoplasia

Endoscopic mucosal resection (EMR) was developed for the purpose of preserving complete gastrointestinal function after the resection of a lesion limited to the mucosa of the digestive tract, as well as for obtaining larger specimens that would enable a precise histopathologic diagnosis. In Japan, different techniques were developed for EMR that were divided into three modalities: EMR with a do...

متن کامل

SCIENTIFIC LETTERS Endoscopic gastric submucosal dissection in low-grade intraepithelial neoplasia

Endoscopic mucosal resection (EMR) was developed for the purpose of preserving complete gastrointestinal function after the resection of a lesion limited to the mucosa of the digestive tract, as well as for obtaining larger specimens that would enable a precise histopathologic diagnosis. In Japan, different techniques were developed for EMR that were divided into three modalities: EMR with a do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Endoscopy

دوره 44 Suppl 2 UCTN  شماره 

صفحات  -

تاریخ انتشار 2012