Acuity for fine-grain motion and for two-dot spacing as a function of retinal eccentricity: differences in specialization of the central and peripheral retina.
نویسندگان
چکیده
The brief presentation in the peripheral field of two closely spaced luminous point stimuli, in rapid sequence, induces the illusion of a single dot moving over an extended path. This fine-grain movement illusion (FGMI) is particularly compelling under conditions of dark adaptation. The strength of the motion percept, assessed by a rating-scale procedure, was found to correlate well, over different flash-flash onset delays, with an objective measure of the illusion requiring discrimination of the direction of the flash-flash sequence. A direction-discrimination measure was used to determine the minimum dot separation that would reliably elicit an FGMI at retinal eccentricities of 5-25 deg. For comparison, measures of static spatial acuity was made based on the minimum angle of resolution of two simultaneous dot flashes, and on the threshold for discriminating the separation of two simultaneous dot flashes with variable initial spacing. The spatial threshold for FGMI was lower than that for each of the static measures at all peripheral eccentricities, and it increased more slowly with eccentricity than the other spatial thresholds, suggesting the involvement of separate visual pathways for generating percepts of motion and percepts of shape or location. The finding that in the periphery the grain for motion detection was finer than that for spatial discrimination constrains a class of motion-perception models that form an initial spatial description of the stimulus and then compute a temporal derivative.
منابع مشابه
Solar Retinopathy Following Methamphetamine Abuse
Purpose: To report a case of solar retinopathy following methamphetamine (MA) abuse. Case report: A 37-years-old man was visited with sudden painless loss of vision in both eyes. He was addicted to methamphetamine for three years. He used MA at the day of admission. Excessive sun gazing (4 hours) took place due to using hallucinations secondary to the MA. Visual acuity was 15/400 Snellen chart ...
متن کاملSulfur Mustard Exposure and Non-Ischemic Central Retinal Vein Occlusion
A 41-year-old man was referred with a complaint of visual loss in his left eye and his best corrected visual acuity was 20/80. Slit lamp examination showed arborizing conjunctival vessels and dry eye. Fundus examination and fluorescein angiography revealed a non-ischemic central retinal vein occlusion. Cardiovascular, rheumatologic, and hematologic work up showed no abnormal findings. An ascert...
متن کاملPeripheral positional acuity: retinal and cortical constraints on 2-dot separation discrimination under photopic and scotopic conditions.
The precision of discriminating the separation of two dots was measured as a function of separation for eccentricities of 0-10 deg under photopic and scotopic conditions. At each eccentricity, the 2-dot separation discrimination thresholds showed a V-shaped dependence on separation. For separations less than approximately twice the resolution threshold, performance deteriorated from photopic to...
متن کاملVisual short-term memory for natural scenes: Effects of eccentricity.
It is well established that a range of basic visual acuities and sensitivities decline with retinal eccentricity due in part to a decline in spatial sampling in the retina. However, it is also known that not all peripheral deficits can be explained entirely by such low-level factors, suggesting a specialization of central vision for certain visual tasks. Here, we examine visual short-term memor...
متن کاملBias-Induced Optical Absorption of Current Carrying Two-Orbital Quantum Dot with Strong Electron-Phonon Interaction (Polaron Regime)
The one photon absorption (OPA) cross section of a current carrying two-orbital quantum dot (QD) with strong electron-phonon interaction (polaron regime) is considered. Using the self-consistent non-equilibrium Hartree-Fock (HF) approximation, we determine the dependence of OPA cross section on the applied bias voltage, the strength of effective electron-electron interaction, and level spacing ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision research
دوره 29 8 شماره
صفحات -
تاریخ انتشار 1989