Late device embolization in a persistent mitral paravalvular leak.
نویسندگان
چکیده
An 83-year-old man with severe organic mitral regurgitation underwent mitral valve surgery with implantation of a biologic prosthesis. Four months later he presented with hemolytic anemia and heart failure due to severe paravalvular regurgitation. Since the patient refused surgery, the paravalvular leak was closed percutaneously using two Amplatzer devices, with angiographic and clinical success. Two months after the intervention he developed heart failure again and embolization of one of the devices was documented, with significant worsening of paravalvular regurgitation. A redo percutaneous closure was attempted but although initially promising, was ultimately unsuccessful as heart failure symptoms and hemolytic anemia persisted. Surgical correction was the final solution for this case. This is the second case of late device embolization reported in the literature and highlights the importance of careful long-term follow-up of such patients, as late complications, although rare, may occur.
منابع مشابه
Mechanical interference between a closure device and the rigid stent of mitral bioprosthesis: a mechanism for closure device late dislodgement.
: We report here the mechanical interference between mitral bioprostheses and devices currently adopted for percutaneous paravalvular leak closure as a possible cause for late dislodgement and embolization of successfully implanted and apparently stable closure devices.The images included in this study demonstrate that the topographical relationship of the target leak with the bioprosthetic val...
متن کاملRepeated mitral valve replacement in a patient with extensive annular calcification
BACKGROUND Mitral valve replacement in the presence of severe annular calcification is a technical challenge. CASE REPORT A 47-year-old lady who had undergone mitral and aortic valve replacement for rheumatic disease 27 years before presented with dyspnea. At reoperation, extensive mitral annular calcification was hindering the disc motion of the Starr-Edwards mitral prosthesis. The old prost...
متن کاملParavalvular leak closure with the Amplatzer Vascular Plug III device: immediate and short-term results.
INTRODUCTION AND OBJECTIVES Percutaneous paravalvular leak closure is a complex procedure with varying success rates; the lack of closure devices specifically designed for this purpose has hampered this technique. The characteristics of the Amplatzer Vascular Plug III appear to be well suited for paravalvular leak closures; however, the available data are limited to case reports or small series...
متن کاملRepair of paravalvular prosthetic mitral valve leaks with septal occluder devices in severely high-risk patients: a word of caution.
Paravalvular leak following a mitral valve replacement is a complication seen in approximately 1 of 10 replacements. The corrective method has traditionally been reoperation. Septal occluder devices are more commonly being utilized as an alternative percutaneous correction method. We report the use of septal occluder devices in the repair of mitral paravalvular leak in two patients at severely ...
متن کاملPercutaneous retrograde transfemoral closure of mitral paravalvular leak in 3 patients without construction of an arteriovenous wire loop.
Percutaneous closure of paravalvular leaks has emerged as an alternative to repeated surgeries. Different percutaneous techniques and various devices have been used, off-label, for paravalvular leak closure. For mitral leaks, antegrade transseptal, retrograde transfemoral, and retrograde transapical techniques have been developed. In the antegrade transseptal approach, an arteriovenous guidewir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology
دوره 34 4 شماره
صفحات -
تاریخ انتشار 2015