Use of Exergy Analysis to Quantify the Effect of Lithium Bromide Concentration in an Absorption Chiller

نویسندگان

  • Andrew Lake
  • Behanz Rezaie
  • Steven Beyerlein
چکیده

Absorption chillers present opportunities to utilize sustainable fuels in the production of chilled water. An assessment of the steam driven absorption chiller at the University of Idaho, was performed to quantify the current exergy destruction rates. Measurements of external processes and flows were used to create a mathematical model. Using engineering equation solver to analyze and identify the major sources of exergy destruction within the chiller. It was determined that the absorber, generator and condenser are the largest contribution to the exergy destruction at 30%, 31% and 28% of the respectively. The exergetic efficiency is found to be 16% with a Coefficient of performance (COP) of 0.65. Impacts of weak solution concentration of lithium bromide on the exergy destruction rates were evaluated using parametric studies. The studies reveled an optimum concentration that could be obtained by increasing the weak solution concentration from 56% to 58.8% a net decrease in 0.4% of the exergy destruction caused by the absorption chiller can be obtained. The 2.8% increase in lithium-bromide concentration decreases the exergy destruction primarily within the absorber with a decrease of 5.1%. This increase in concentration is shown to also decrease the maximum cooling capacity by 3% and increase the exergy destruction of the generator by 4.9%. The study also shows that the increase in concentration will change the internal temperatures by 3 to 7 ◦C. Conversely, reducing the weak solution concentration results is also shown to increase the exergetic destruction rates while also potentially increasing the cooling capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exergy Analysis of a Novel Combined System Consisting of a Gas Turbine, an Organic Rankine Cycle and an Absorption Chiller to Produce Power, Heat and Cold

The current work investigates the exergy analysis of a new system to generate power, heat, and refrigeration. In the proposed system, the heat loss of a gas turbine (GT) is first recovered by a Heat Recovery Steam Generator (HRSD), then by an Organic Rankine Cycle (ORC) to generate warm water and additional power, respectively. In the ORC, reheating is used to increase the output power, the req...

متن کامل

Thermoeconomic analysis of a hybrid PVT solar system integrated with double effect absorption chiller for cooling/hydrogen production

A novel solar-based combined system which is consisting of a concentrated PV, a double effect LiBr-H2O absorption chiller, and a Proton Exchange Membrane (PEM) is proposed for hydrogen production. A portion of the received energy is recovered to run a double effect absorption chiller and the rest is turned into electricity, being consumed in the PEM electrolyzer for hydrogen producti...

متن کامل

Advanced Exergy Analysis for a Solar Double Stage Absorption Chiller

.............................................................................................................................. i List of Figures ................................................................................................................... vi List of Tables .................................................................................................................... i...

متن کامل

Comparison and Analysis of Lithium Bromide-water Absorption Chillers Using Plastic Heat Transfer Tubes and Traditional Lithium Bromide-water Absorption Chillers

There are extensive applications of lithium bromide-water absorption chillers in industry, but the heat exchangers corrosion and refrigerating capacity loss are very difficult to be solved. In this paper, an experiment was conducted by using plastic heat transfer tubes instead of copper tubes. As an example, for a lithium bromide-water absorption chiller of refrigerating capacity of 35kW, the c...

متن کامل

The development and assessment of solar-driven Tri-generation system energy and optimization of criteria comparison

In this research, the thermodynamic investigation of the tri-generation system is performed by the first and second law of Thermodynamics. The trigeneration system under study consists of three subsystems including the solar subsystem, Kalina subsystem and lithium bromide-water absorption chiller subsystem. The proposed system generates power, cooling and hot water using solar energy. The syste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Entropy

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2017