Evaluation of a novel (18)F-labeled positron-emission tomography perfusion tracer for the assessment of myocardial infarct size in rats.

نویسندگان

  • Hossam M Sherif
  • Antti Saraste
  • Eliane Weidl
  • Axel W Weber
  • Takahiro Higuchi
  • Sybille Reder
  • Thorsten Poethko
  • Gjermund Henriksen
  • David Casebier
  • Simon Robinson
  • Hans-Jürgen Wester
  • Stephan G Nekolla
  • Markus Schwaiger
چکیده

BACKGROUND The goal of this study was to evaluate a new (18)F-labeled positron-emission tomography (PET) perfusion tracer, (18)F BMS747158-02, for the assessment of myocardial infarct (MI) size. METHODS AND RESULTS Wistar rats were studied 24 hours after ligation of the left coronary artery either permanently (n=15) or transiently (n=16) for 30 minutes. Seven nonoperated rats were studied as controls. The rats were injected with 37 MBq of (18)F BMS747158-02 and imaged with a small animal PET scanner for 20 minutes. Polar maps were generated for measurement of PET defect size, and left ventricular systolic and diastolic volumes were assessed in gated images. As a reference, MI size was determined by 2,3,5-triphenyltetrazolium chloride staining of left ventricular tissue samples. Permanent or transient ligation of the left coronary artery produced transmural or subendocardial MI of variable sizes, respectively. In normal rats, PET imaging demonstrated intense and homogeneous uptake of (18)F BMS747158-02 throughout the myocardium. After ligation, sharply defined perfusion defects were present. Throughout the imaging period, the defect size correlated closely with the MI size either after permanent (r=0.88; P<0.01; mean difference, 1.86%) or transient (r=0.92; P<0.01; mean difference, 2.16%) ligation of the left coronary artery. Moreover, reduction of left ventricular systolic function measured with PET correlated with the MI size (r=-0.81; P<0.01; n=23). CONCLUSIONS Myocardial (18)F BMS747158-02 PET imaging provides excellent image quality and uptake properties, enabling accurate evaluation of MI size and left ventricular function in rats. It is a promising technique for evaluation of MI size in clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

F-Labeled Positron-Emission Tomography Perfusion Tracer for the Assessment of Myocardial Infarct Size in Rats

Background—The goal of this study was to evaluate a new F-labeled positron-emission tomography (PET) perfusion tracer, F BMS747158-02, for the assessment of myocardial infarct (MI) size. Methods and Results—Wistar rats were studied 24 hours after ligation of the left coronary artery either permanently (n 15) or transiently (n 16) for 30 minutes. Seven nonoperated rats were studied as controls. ...

متن کامل

A novel (18)F-labeled tracer for the quantification of myocardial blood flow and infarct size with positron-emission tomography: another way to avoid the need of an on-site cyclotron.

Currently, nuclear imaging techniques can be used to diagnose coronary macrovascular and microvascular disease and to measure infarct size and left ventricular ejection fraction. Semiquantitative assessment of regional myocardial perfusion with single-photon emission computed tomography is a noninvasive, robust, and widely available method of assessing myocardial ischemia and has an established...

متن کامل

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

Evaluation of the Novel Myocardial Perfusion Positron-Emission Tomography Tracer

Background—Positron-emission tomography (PET) tracers for myocardial perfusion are commonly labeled with short-lived isotopes that limit their widespread clinical use. F-BMS-747158-02 (F-BMS) is a novel pyridaben derivative that was evaluated for assessment of myocardial perfusion by comparison with N-ammonia (NH3) and with radioactive microspheres in a pig model. Methods and Results—Fourteen p...

متن کامل

Research Progress on 18F-Labeled Agents for Imaging of Myocardial Perfusion with Positron Emission Tomography.

Coronary artery disease (CAD) is the leading cause of death in the world. Myocardial perfusion imaging (MPI) plays a significant role in non-invasive diagnosis and prognosis of CAD. However, neither single-photon emission computed tomography nor positron emission tomography clinical MPI agents can absolutely satisfy the demands of clinical practice. In the past decades, tremendous developments ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 2 2  شماره 

صفحات  -

تاریخ انتشار 2009