Letter to the Editor: Adverse Reactions of Artificial Bone Graft Substitutes: Lessons Learned From Using Tricalcium Phosphate geneX®
نویسندگان
چکیده
To the editor: The paper by Friesenbichler and colleagues [2] reported the findings of a truncated clinical study involving 31 patients treated for bone tumors by curettage, and filling of the defect using geneX (Biocomposites Ltd., Staffordshire, UK). ‘‘The reconstructive approach after intralesional curettage is controversial and clinical practice varies,’’ the authors reported. ‘‘Polymethylmethacrylate (PMMA), allografts or autografts have been used in several studies and complication rates up to 33% have been reported’’ [2]. The authors reported the use of geneX in 31 patients, of which 26 patients had no complications. Based on these figures alone, these data represent a 16% complication rate — less than the 33% quoted above when using allografts and autografts. Two patients (Patients 21 and 30) developed a postoperative soft tissue cyst at 52 and 55 days respectively, which reduced in size within 2 months without surgical intervention. One of these patients (Patient 30) also received an allograft and a Vitoss Bone Graft Substitute from Stryker Orthopaedics (Mahwah, NJ, USA) — a fact not reported in this article. In accordance with the medical device regulations, an investigation and visit by our regulatory department was carried out. This visit revealed the concurrent use of Vitoss in one of the cases. Three patients (Patients 2, 25, and 31) had postoperative aseptic inflammation. One of the patients, a 14-year-old juvenile identified as a worst case, also received allograft. This patient required revision surgery 1 month after surgery, and presented with severe damage to the skin. Histology showed a chronic, lymphocytic inflammation with plasma cells. It is questionable to attribute these adverse reactions to the presence of geneX alone considering the concurrent use of allograft. The authors believed one of the reasons for the inflammation and soft tissue cyst formation was the overfilled and pressurized defect site when using allografts. The Instructions For Use for geneX advise against overfilling or pressurizing the treatment site, and also recommend not adding other substances to the product. To conclude that this type of bone substitute should not be used in the treatment of bony defects as a result of these data would appear presumptuous, and not warranted on the strength of the outcomes. The comments made regarding the Saadoun paper [3] would suggest that the authors did not read the published response [1] or the clarification statement subsequently published by the authors [4]. geneX is cleared as a Class II medical device by the FDA, CE marked in accordance (RE: Friesenbichler J, Maurer-Ertl W, Sadoghi P, Pirker-Fruehauf U, Bodo K, Leithner A. Adverse Reactions of Artificial Bone Graft Substitutes: Lessons Learned From Using Tricalcium Phosphate geneX. [Published online ahead of print September 28, 2013]. Clin Orthop Relat Res. DOI: 10.1007/s11999-013-3305-z.) Both authors (P. A. Laycock and J. J. Cooper) are employees of Biocomposites Ltd., Staffordshire, UK. All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research editors and board members are on file with the publication and can be viewed on request. The opinions expressed are those of the writers, and do not reflect the opinion or policy of CORR or the Association of Bone and Joint Surgeons.
منابع مشابه
Lytic Complications after Skull Reconstruction Using GeneX®.
Multiple methods and materials are available for bone defect reconstruction. Bone graft substitute is one of the materials used for reconstruction of bone defect and have been widely used recently. This report describes some cases about complications related to GeneX® which is introduced as mixture of calcium sulfate and β-tricalcium phosphate at manufacturer's official web site. It informed of...
متن کاملCritical Size Bone Defect Healing Using Collagen–Calcium Phosphate Bone Graft Materials
The need for bone graft materials to fill bony voids or gaps that are not related to the intrinsic stability of the bone that arise due to trauma, tumors or osteolysis remains a clinically relevant and significant issue. The in vivo response of collagen-tricalcium phosphate bone graft substitutes was evaluated in a critical size cancellous defect model in skeletally mature rabbits. While the ma...
متن کاملBone grafts and their substitutes.
The continual cycle of bone formation and resorption is carried out by osteoblasts, osteocytes, and osteoclasts under the direction of the bone-signaling pathway. In certain situations the host cycle of bone repair is insufficient and requires the assistance of bone grafts and their substitutes. The fundamental properties of a bone graft are osteoconduction, osteoinduction, osteogenesis, and st...
متن کاملComputational Intelligence
We give a brief introduction to computational intelligence application in medicine. We review medical image processing in magnetic resonance images and nondestructive evaluation studies by ultrasonic systems. Primary processes of medical image processing are segmentation, registration and enhancement. In them, automated segmentation is received much considerable attentions. In general, several ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 472 شماره
صفحات -
تاریخ انتشار 2014