Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery

نویسندگان

  • Yubo Wu
  • Songyu Liu
  • Rongfeng Liao
چکیده

BACKGROUND This study aimed to evaluate the prediction accuracy of postoperative refractions using partial coherence interferometry (IOL-Master) and applanation ultrasound (AL-3000) assisted with corneal topography (TMS-4) in eyes that had undergone myopic laser-assisted in situ keratomileusis (LASIK). METHODS Haigis-L formula, Koch-Maloney method using Haigis formula, Shammas clinically derived K-value (simulated keratometric value) correction (Shammas c.d.) using Haigis formula, and Shammas post-LASIK (Shammas-PL) formula were used in eyes with myopic LASIK. Constants were derived from the optimized constants in 133 virgin eyes. Refractive outcomes were determined by streak retinoscopy and subjective manifest refraction. Methods and formulas were evaluated by mean error (ME), standard deviation (SD), range of error, mean absolute error (MAE), median absolute error, 95% confidence interval of MAE, and percentage of eyes within ±0.5 diopter (D), ±1.0 D, and ±1.5 D of prediction. RESULTS SDs of the Haigis-L, Koch-Maloney method using the Haigis formula, Shammas c.d. using the Haigis formula, and the Shammas-PL formula using IOL-Master were 0.721, 0.695, 0.695, and 0.698; and those using AL-3000 assisted with TMS-4 were 0.782, 0.741, 0.743, and 0.778, respectively. CONCLUSIONS No-history methods that corrected corneal power with measurements using IOL-Master were promising in myopic post-LASIK eyes, but still a gap in prediction accuracy exists between virgin eyes and post-LASIK eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Intraocular lens power calculations in eyes with previous corneal refractive surgery].

Results of intraocular lens power calculation were lower than actual required power in eyes with previous corneal refractive surgery because the inaccurate readings of corneal power obtained from standard keratometry. This causes the unacceptable hyperopia after cataract surgery. With increasing of population undergone excimer laser refractive surgery, this problem will be an obvious problem in...

متن کامل

No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis.

PURPOSE To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING Private practice, Lynwood, California, USA. METHODS The predicted IOL power was calculated in each case. Also calculated were the mean arith...

متن کامل

Intraocular Lens Power Calculation after Corneal Refractive Surgery

PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) fo...

متن کامل

Intraocular Lens Power Calculation after Refractive Surgery: A Comparative Analysis of Accuracy and Predictability

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation using conventional regression formulae or the American Society of Cataract and Refractive Surgery (ASCRS) IOL power calculator for previous corneal refractive surgery. METHODS We retrospectively reviewed 96 eyes from 68 patients that had undergone cataract surgery after keratorefractive surgeries. We calculated the fo...

متن کامل

Prediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye

Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...

متن کامل

Intraocular lens power calculatio n after corneal refractive surgery

Current Opinion in Ophthalmology 2008, 19:357–362 Purpose of review Corneal refractive procedures have become increasingly popular over the past decade allowing patients to have excellent uncorrected visual acuity and spectacle independence. As these individuals mature, many will eventually undergo cataract surgery. With the advances in modern cataract surgery and lens implant technology, parti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017