Total hip arthroplasty via the direct anterior approach with Kerboull-type acetabular reinforcement device for an elderly female with factor XI deficiency

نویسندگان

  • Kei Sano
  • Yasuhiro Homma
  • Tomonori Baba
  • Jun Ando
  • Mikio Matsumoto
  • Hideo Kobayashi
  • Takahito Yuasa
  • Kazuo Kaneko
چکیده

We present a case of successful and uncomplicated total hip arthroplasty with an acetabular reinforcement device in an elderly patient with hip osteoarthritis already diagnosed with factor XI deficiency, which is a very rare bleeding disorder and at high risk of post-operative haemorrhage, and it poses a substantial challenge to surgeons as a consequence of the specific risks of infection and fixation failure. Moreover, bone fragility in elderly patient increases potential risk of adverse event. Fresh frozen plasma was used to supplement factor XI activity. Importantly, transfusion-transmitted disease such as having factor XI inhibitor was promptly surveyed prior to the supplement since the patient had previous history of the administration of fresh frozen plasma. Under prompt and effective peri-operative haemostasis, rigid implant fixation and rigorous attention to the prevention of infection seem to achieve the best possible outcomes for elderly patients with a bleeding disorder undergoing total hip arthroplasty.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone Remodeling in Acetabular Reconstruction Using a Kerboull-Type Reinforcement Device and Structural Bone-Grafting in Total Hip Arthroplasty.

BACKGROUND The purpose of this study was to identify the long-term durability of the Kerboull-type reinforcement device (KT plate) in acetabular reconstruction for massive bone defects, assessing the remodeling of structural bone grafts. METHODS This study retrospectively evaluated 106 hips that underwent acetabular reconstruction using a KT plate between November 2000 and December 2010. Thir...

متن کامل

Revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device with bone allograft: minimum 4.5-year follow-up results and mechanical analysis.

We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts ...

متن کامل

Kerboull-type plate in a direct anterior approach for severe bone defects at primary total hip arthroplasty: technical note

INTRODUCTION For cases with extensive acetabular bone defects, we perform surgery combining the Kerboull-type (KT) plate and bone graft through direct anterior approach (DAA) in primary total hip arthroplasty (THA) requiring acetabular reconstruction as minimally invasive surgery. This paper provides the details of the surgical procedure. METHODS The basic structure of the Kerboull-type plate...

متن کامل

Risk factors for failure of revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device

BACKGROUND The present study aimed to identify the risk factors associated with revision total hip arthroplasty (THA) failure using a Kerboull-type (KT) plate. METHODS We analyzed 77 revision THAs using cemented acetabular components with a KT plate for aseptic loosening between May 2000 and March 2012. We examined the association of bone graft type, acetabular bone defects, age at the time o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017