Spatial channel interactions in cochlear implants.
نویسندگان
چکیده
The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal side. In contrast, the evoked compound action potential and perceptual channel interaction data showed much greater individual variability. It is likely that actual reduction in neural and higher level interactions, instead of simple sharpening of the electric current field, would be the key to predicting and hopefully improving the variable cochlear implant performance. The present results are obtained with auditory prostheses but can be applied to other neural prostheses, in which independent spatial channels, rather than a high stimulation rate, are critical to their performance.
منابع مشابه
Comparison of Auditory Perception in Cochlear Implanted Children with and without Additional Disabilities
Background: The number of children with cochlear implants who have other difficulties such as attention deficiency and cerebral palsy has increased dramatically. Despite the need for information on the results of cochlear implantation in this group, the available literature is extremely limited. We, therefore, sought to compare the levels of auditory perception in children with cochlear implant...
متن کاملVirtual channel discrimination is improved by current focusing in cochlear implant recipients.
Cochlear implant users' spectral resolution is limited by both the number of implanted electrodes and channel interactions between electrodes. Current steering (virtual channels) between two adjacent monopolar electrodes has been used to increase the number of spectral channels across the electrode array. However, monopolar stimulation is associated with large current spread and increased chann...
متن کاملThe Importance of Human Cochlear Anatomy for the Results with Modiolus Hugging Multi-Channel Cochlear Implants
Hypothesis: The fact that the anatomy of the basal turn of the human cochlea, especially, is essentially different from that of other species is likely to influence the outcome of cochlear implantation. Background: Multichannel cochlear implants give better speech understanding than single-channel devices. They are intended to make use of the tonotopic organization of the cochlea by selectively...
متن کاملSpeech Perception in Children with Cochlear Implants
Cochlear implants provide access to the speech signal in children with hearing loss that often cannot benefit from acoustic hearing aids. However, despite the numerous positive results in pediatric cochlear implantation, published data still indicated a wide range of performance among implant recipients. Hence, a need to study the possible variables that can affect performance, could account fo...
متن کاملComparison of the high-frequency morpho-syntactic structures of cochlear implant children and children with normal hearing aged 4-6 years
Introduction: Children with cochlear implants experience problems at all language domains, and have more problems in morpho-syntactic skills than others domains. Considering the importance of morphology and syntax in developing of communication skills of children, this study compared the use of high-frequency morpho-syntactic structures among 4-6 years old children with cochlear implants and ty...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neural engineering
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2011