Vertical optic disk diameter: discrepancy between planimetric and SLO measurements.
نویسندگان
چکیده
PURPOSE To compare measurements of the vertical diameter of the optic disk using the Heidelberg Retinal Tomograph (HRT) and planimetric methods. METHODS On the HRT, three measurements of the vertical disk diameter were made on 32 eyes from a composite image using the circle draw facility and were compared with three measurements of the central image of the 32 tomographic cuts. These were repeated by a second observer. Measurements were compared with those obtained from photographs using the three corrections described by Bengtsson and Krakau. RESULTS For the HRT, there was minimal intraobserver variation, coefficient of variation (1.515% to 1.882% for the two observers). Interobserver variation was also small (CoV 1.969%). The authors found the closest agreement with the HRT measurements using regression analysis was obtained using correction 3 (r = 0.8258). HRT measurements were significantly smaller (P < 0.0001) by a constant amount of 0.13 mm across the range of optic disk size. There was a significant difference between the HRT measurement of the composite image and the central cut (P = 0.0003 for observer 1). CONCLUSIONS HRT measurements are significantly smaller than those from photographs and, therefore, are not interchangeable.
منابع مشابه
Automated volumetric evaluation of stereoscopic disc photography
PURPOSE To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS One hundred twenty-two stereoscopic optic disc pho...
متن کاملAssessment of β-zone peripapillary atrophy by optical coherence tomography and scanning laser ophthalmoscopy imaging in glaucoma patients
PURPOSE To assess β-zone peripapillary atrophy (β-PPA) using spectral domain optical coherence tomography (SD-OCT), scanning laser ophthalmoscopy (SLO), and fundus auto-fluorescence (FAF) imaging in patients with primary open-angle glaucoma with advanced glaucomatous visual field defects. METHODS A consecutive, prospective series of 82 study eyes with primary open-angle glaucoma were included...
متن کاملAging changes of the optic nerve head in relation to open angle glaucoma.
AIMS To determine the age related changes in optic nerve head structure in a group of normal subjects and assess the significance of any changes in relation to those found in open angle glaucoma. METHODS A group of 88 white volunteers and friends and spouses of patients with a normal visual field and normal intraocular pressure was studied. Two different imaging and measurement devices were u...
متن کاملOphthalmoscopic-Perspectively Distorted Optic Disc Diameters and Real Disc Diameters.
PURPOSE To investigate the difference between two-dimensionally measured disc diameters (DDs) based on fundus images and three-dimensionally measured DDs based on enhanced depth imaging optical coherence tomography (EDI-OCT). METHODS The DDs were three-dimensionally measured on EDI-OCT images of optic nerve heads and two-dimensionally measured on near-infrared reflectance fundus images in 90 ...
متن کاملHigh-Resolution Imaging of the Retinal Nerve Fiber Layer in Normal Eyes Using Adaptive Optics Scanning Laser Ophthalmoscopy
PURPOSE To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO). METHODS AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a mont...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 36 5 شماره
صفحات -
تاریخ انتشار 1995