Stroke volume obtained by electrical interrogation of the brachial artery: transbrachial electrical bioimpedance velocimetry.

نویسندگان

  • Donald P Bernstein
  • Isaac C Henry
  • Mathew J Banet
  • Teri Dittrich
چکیده

The goal of this study is to measure left ventricular stroke volume (SV) from the brachial artery (BA) using electrical bioimpedance. Doppler-derived SV was used for comparison. Twenty-nine healthy adults were recruited for study. Doppler echocardiographic-derived SV was obtained from the product of distal left ventricular outflow tract cross-sectional area and systolic velocity integral. SV from the BA was obtained by transbrachial electrical bioimpedance velocimetry (TBEV). Application of a current field across the left brachium was effected by injection of a constant magnitude, high frequency, low amperage, alternating current. Therein, a static voltage (U(0)) and pulsatile voltage change (ΔU(t)) were measured and converted to their corresponding impedances, Z(0) and ΔZ(t). TBEV-derived SV was obtained by multiplying a square root value of the normalized, acceleration-based, peak first time derivative of ΔZ(t) by a volume conductor and systolic flow time. Inter-method agreement was determined by the Bland-Altman method. To assess the contribution of blood resistivity variations to ΔZ(t), BA diameters were measured at end-diastole and peak systolic expansion. Results indicate that since the BA demonstrates parabolic, laminar flow, with minimal diameter changes, blood resistivity variations are likely responsible for the derived impedance changes. Bland-Altman analysis shows that SV is obtainable by TBEV from healthy humans at rest.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac outputy

Background. Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophagea...

متن کامل

Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.

BACKGROUND Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophageal...

متن کامل

Rapid Recanalization Using TrevoProVue through a 4.2 Fr Catheter without a Guiding Catheter via Transbrachial Approach: A Case Report

Mechanical thrombectomy with a stent retriever has been reported to achieve high rates of successful recanalization, and reduce disability and mortality in patients with acute ischemic stroke (AIS) due to proximal vessel occlusion. However, in a few cases, the treatment is difficult due to artery tortuosity or other factors. The authors present a case of a 94-year-old man presenting with acute ...

متن کامل

Electrical Bioimpedance Spectroscopy on Acute Unilateral Stroke Patients: Initial Observations regarding Differences between Sides

PURPOSE Electrical Bioimpedance Cerebral Monitoring is assessment in real time of health of brain tissue through study of passive dielectric properties of brain. During the last two decades theory and technology have been developed in parallel with animal experiments aiming to confirm feasibility of using bioimpedance-based technology for prompt detection of brain damage. Here, for the first ti...

متن کامل

The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients

The aim of the present study was to test the validity of the transthoracic electrical bioimpedance method PhysioFlow® to measure stroke volume in patients with chronic anemia. Stroke volume index (SVI), as well as cardiac index (CI) obtained by transthoracic electrical bioimpedance method and doppler echocardiography were compared in healthy subjects (n = 25) and patients with chronic anemia (i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physiological measurement

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2012