Scanning and Image Reconstruction Techniques in Confocal Laser Scanning Microscopy

نویسندگان

  • Peng Xi
  • Yujia Liu
  • Qiushi Ren
چکیده

Taking advantage of the laser scanning methodology, confocal microscopy has been widely applied in cutting-edge biological research for its three-dimensional, high-resolution imaging capability (Pawley 1995). The principles of confocal were put forward by Marvin Minsky in 1955 (Minsky 1988), yet the experimental demonstration was not accomplished until 20 years later by Cremer brother (Cremer, Cremer et al. 1978), and Brakenhoff et al. (Brakenhoff, Blom et al. 1979). In confocal microscopy, one or more focal spots are scanned relative to the specimen, to extract the signal from the focal spots. The 3-D image can then be reconstructed digitally. Contrary to mechanically scanning the specimen, which is relatively slow as the specimen has to be moved, the laser provides fast scanning and imaging speed for confocal microscopy and therefore is routinely used in commercial state-of-the-art confocal systems. Several laser scanning mechanisms have been employed in confocal microscopy: 1. single spot laser scan with galvanometers; 2. single spot laser scan for real-time imaging and endoscopy; 3. line scan confocal with a line detector or a 2-D detector; 4. multiple spot scanning with 2-D detectors. The single spot galvanometric scan is the most straightforward laser scanning mechanism, which provides an imaging speed of ~1 frame(s) per second (fps) for a typical 512 x 512 image, and is widely used in many confocal laser scanning systems. However, the relatively slow scanning speed of the galvanometer commonly used in a confocal laser scanning microscopy can dramatically limit the system performance in scanning speed and image quality if the data collection is simply synchronized to the galvanometric scanning. In Section 2 we discuss the command and data processing techniques for galvanometric scanning, for example, pixel delay and interlace line switching can be applied on bidirectional scans to cancel aliasing; pixel binning and/or image average can be used to improve the signal-to-noise level; Acquire-On-Fly scanning can be applied when the signal command is a limiting factor for the imaging speed. Due to the limitations placed on maximum galvanometer scanning speed, real-time confocal microscopy relies on the fast scanning mechanism on its fast axis, such as a resonant scanner or rotational polygon mirror. This is discussed in Section 3. The resonant scanner runs at a fixed frequency with variable amplitude, and scans a temporal sinusoidal pattern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional Reconstruction of Large Tissue Volumes From Scanning Laser Confocal Microscopy

Phase correlation is applied to the mosaicing of confocal scanning laser microscopy data. A large specimen (i.e., a murine heart) is cut into a number of individual sections with appropriate thickness. The sections are scanned horizontally and vertically to produce tiles of a 3D volume. Image processing based on phase correlation is used to rebuild the 3D volume and stitch the tiles together. S...

متن کامل

Blind Deconvolution in 3d Biological Microscopy

Confocal microscopy o ers several advantages over conventional optical microscopy with its small depth-ofeld, its reduction of out-of-focus blur, and its full three-dimensional (3D) image scanning ability. For biomedical applications, it can also acquire images of living cells, usually labeled with one or more uorescent probes. The confocal laser scanning microscope (CLSM) is an optical uoresce...

متن کامل

Confocal laser scanning microscopy and three-dimensional reconstruction of cell clusters in serous fluids.

Thick cell clusters are a common finding in reactive and malignant effusions. In order to arrive at a diagnosis, clusters are evaluated for certain cytomorphologic features including size, shape, smooth vs. scalloped borders, and three-dimensional (3-D) configuration. By conventional microscopy, the image of these clusters is often blurred due to limitations in resolution. Consequently, the exa...

متن کامل

REVIEW Confocal scanning optical microscopy and its applications for biological specimens

Confocal scanning optical microscopy (CSOM) is a new optical microscopic technique, which offers significant advantages over conventional microscopy. In laser scanning optical microscopy (SOM), the specimen is scanned by a diffractionlimited spot of laser light, and light transmitted or reflected by the in-focus illuminated volume element (voxel) of the specimen, or the fluorescence emission ex...

متن کامل

Real-time mapping of the subepithelial nerve plexus by in vivo confocal laser scanning microscopy.

AIM To produce two-dimensional reconstruction maps of the subepithelial nerve plexus (SEP) in living cornea by in vivo laser scanning confocal microscopy in real time. METHODS In vivo confocal laser scanning microscopy (Heidelberg Retinal Tomograph II in conjunction with the Rostock Cornea Module) was performed on normal eyes (n=6) and eyes after laser-assisted in situ keratomileusis (LASIK) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012