Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE This study was performed to compare three disposable airway devices, the LMA Unique (LMA-U), the Ambu laryngeal mask (Ambu LM) and the Soft Seal laryngeal mask (Soft Seal LM) for elective general anaesthesia during controlled ventilation in non-paralysed patients. METHODS One hundred and twenty ASA I-III patients scheduled for routine minor obstetric surgery were randomly allocated to the LMA-U (n = 40), Ambu LM (n = 40) or Soft Seal LM (n = 40) groups, respectively. Patients were comparable with respect to weight and airway characteristics. A size 4 LMA was used in all patients and inserted by a single experienced anaesthesiologist. Oxygenation, overall success rate, insertion time, cuff pressure and resulting airway leak pressure were determined as well as a subjective assessment of handling and the incidence of sore throat, dysphagia and hoarseness. RESULTS Time of insertion was shortest with the Ambu LM, while failure rates were comparable with the LMA-U, the Ambu LM and the Soft Seal LM (median 19 s; range 8-57 s; success rate 100% vs. 14; 8-35; 97% vs. 20; 12-46; 95%). Insertion was judged 'excellent' in 75% of patients in the LMA-U group, in 70% of patients in Ambu LM group and in 65% of patients in the Soft Seal LM group. There was no difference between devices with respect to postoperative airway morbidity at 6 h or 24 h following surgery. CONCLUSIONS All three disposable devices were clinically suitable with respect to insertion times, success rates, oxygenation, airway and leak pressures, as well as to subjective handling and postoperative airway morbidity.
منابع مشابه
Comparison between LMA-Classic and AMBU AuraOnce laryngeal mask airway in patients undergoing elective general anaesthesia with positive pressure ventilation.
BACKGROUND The LMA-Classic laryngeal mask airway (Classic LMA) is an autoclavable and reusable laryngeal mask airway with strong evidence supporting its efficacy and safety. Due to the concern of infection risk particularly of prion disease, various single-use laryngeal mask devices were developed. The Ambu AuraOnce LMA (Ambu LMA) is a single use disposable laryngeal mask airway with special de...
متن کاملLimitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملRandomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I-IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic an...
متن کاملCOMPARISON BETWEEN THE EFFICACY OF TRAPEZIUS SQUEEZING TEST AND JAW THRUST MANEUVER FOR PREDICTION OF SUCCESSFUL INSERTION OF LARYNGEAL MASK AIRWAY
Background & Aims: The aim of this study was to compare trapezius squeezing and jaw thrust to evaluate suitable conditions for laryngeal mask airway (LMA) insertion. Materials & Methods: In this clinical trial study, 138 patients with ASA physical status 1 or 2 who were candidates for elective surgery of shin fracture were randomly assigned into one of the groups of trapezius squeeze and raisi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of anaesthesiology
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2007