Simplified spectral phase interferometry for direct electric-field reconstruction by using a thick nonlinear crystal.
نویسندگان
چکیده
We propose and demonstrate a novel implementation of spectral-shearing interferometry (SSI) for reconstructing the electric field of ultrashort pulses by utilizing asymmetric group velocity matching in a long nonlinear crystal. The proposed configuration eliminates the requirement for a linearly chirped auxiliary pulse that is in common in all existing SSI methods, relying on nonlinear conversion to produce a spectral shear.
منابع مشابه
Gold-SPIDER: spectral phase interferometry for direct electric field reconstruction utilizing sum-frequency generation from a gold surface
We report on a version of spectral phase interferometry for direct electric field reconstruction (SPIDER) that uses no nonlinear crystals, instead relying on the harmonic signal from a gold mirror. Surface harmonic generation holds the promise of being able to upconvert extremely broad bandwidths over a large tuning range, thus providing access to both extremely short pulses and wavelengths out...
متن کاملCharacterization of a broadband pulse for phase controlled multiphoton microscopy by single beam SPIDER.
We present what we believe to be a new version of spectral phase interferometry for direct electric field reconstruction (SPIDER) using only a single-phase and polarization controlled laser beam. Two narrow pulses and one broadband pulse are selected out of an ultrafast laser pulse by a polarization and phase control technique to generate second harmonic generation (SHG) signals, which are equi...
متن کاملShaper-assisted collinear SPIDER: fast and simple broadband pulse compression in nonlinear microscopy
In situ characterization and control of the phase of broadband femtosecond pulses in microscopy can be achieved with a novel simplified scheme based on spectral shear interferometry for direct electric field reconstruction (SPIDER): the use of a femtosecond pulse shaper eliminates the need for an interferometer setup, allows dispersion-free SPIDER operation and at the same time compression even...
متن کاملSingle-beam homodyne SPIDER for multiphoton microscopy.
We report a new version of spectral phase interferometry for direct electric field reconstruction (SPIDER) requiring only a single phase-shaped laser beam. A narrowband probe pulse is selected out of a broadband ultrafast laser pulse by a phase pulse-shaping technique and mixed with the original broadband pulse to generate a second-harmonic generation (SHG) signal. Using another SHG signal sole...
متن کاملSensitivity improvement of spectral phase interferometry for direct electric-field reconstruction for the characterization of low-intensity femtosecond pulses
A modified-SPIDER (spectral phase interferometry for direct electric-field reconstruction) technique where external powerful optical pulses are employed as a light source of chirped reference pulses for sum-frequency generation is proposed and is demonstrated experimentally. It provides great improvements in sensitivity and signal-to-noise ratio, and will enable a single-shot measurement for a ...