Determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations using derivative spectrophotometry and chromatographic-densitometric method.
نویسندگان
چکیده
Two methods, spectrophotometric and chromatographic-densitometric ones, were developed for determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations. Spectrophotometric method involved derivative spectrophotometry and zero order spectrophotometry. The measurements were carried out at lambda = 224.0 nm for quinapril, lambda = 261.0 nm for hydrochlorothiazide and lambda = 270.0 nm for losartan when the derivative spectrophotometry was applied and lambda = 317.0 nm when zero order spectrophotometry was applied for the determination of hydrochlorothiazide. In chromatographic-densitometric studies high performance thin layer chromatography (HPTLC) plates were used as stationary phase and a mixture of solvents n-butanol : acetic acid : water (15 : 5 : 1, v/v/v) as mobile phase. Under the established conditions good resolution of examined constituents was obtained. Retardation factor for quinapril hydrochloride was R(f) - 0.70, for losartan potassium R(f) - 0.85 and for hydrochlorothiazide R(f) - 0.78. The developed methods are characterized by high sensitivity and accuracy. For quantitative analysis, densitometric measurements were carried out at lambda = 218.0 nm for quinapril, lambda = 275.0 nm for hydrochlorothiazide and = 232.0 nm for losartan.
منابع مشابه
Simultaneous Determination of Losartan and Hydrochlorothiazide in Pharmaceutical Preparations by Derivative and Ratio Derivative Spectrophotometry
Background & Aims: Losartan is a non-peptide potent antihypertensive agent that acts through blocking angiotensin II receptors. Hyzaar® is a combination product that contains two drugs, losartan and hydrochlorothiazide, used to lower high blood pressure. There are some reports regarding simultaneous measurement of the drugs in pharmaceutical and biological samples which includes HPLC, CE, CEC, ...
متن کاملQuantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations
Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...
متن کاملQuantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations
Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...
متن کاملSimultaneous determination of hydrochlorothiazide and benazepril hydrochloride or amiloride hydrochloride in presence of hydrochlorothiazide impurities: chlorothiazide and salamide by HPTLC method.
Simple, selective and sensitive high-performance thin layer chromatographic (HPTLC) method has been developed and validated for the simultaneous determination of hydrochlorothiazide (HCZ) in the presence of its impurities (chlorothiazide (CT) and salamide (DSA)), in two quaternary mixtures with benazepril hydrochloride (BZ) or amiloride hydrochloride (AM). The separation was carried out on HPTL...
متن کاملValidated HPTLC Method for Simultaneous Determination of Quinapril Hydrochloride and Hydrochlorothiazide in a Tablet Dosage Form
Quinapril hydrochloride and hydrochlorothiazide were simultaneously determined by HPTLC in pharmaceutical formulations. The drugs were separated on silica gel 60 F(254) plates using suitable combination of solvents as mobile phase. The validation parameters, tested in accordance with the requirements of ICH guidelines, prove the suitability of methods.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta poloniae pharmaceutica
دوره 70 6 شماره
صفحات -
تاریخ انتشار 2013