Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye?

نویسندگان

  • Ana-Maria Simundic
  • Nora Nikolac
  • Valentina Ivankovic
  • Dragica Ferenec-Ruzic
  • Bojana Magdic
  • Marina Kvaternik
  • Elizabeta Topic
چکیده

BACKGROUND Results from hemolyzed, icteric, and lipemic samples may be inaccurate and can lead to medical errors. These preanalytical interferences may be detected using visual or automated assessment. Visual inspection is time consuming, highly subjective and not standardized. Our aim was to assess the comparability of automated spectrophotometric detection and visual inspection of lipemic, icteric and hemolyzed samples. METHODS This study was performed on 1727 routine biochemistry serum samples. Automated detection was performed using the Olympus AU2700 analyzer. We assessed: 1) comparability of visual and automated detection of lipemic, icteric and hemolyzed samples, 2) precision of automated detection, and 3) inter-observer variability for visual inspection. RESULTS Weighted kappa coefficients for comparability of visual and automated detection were: 0.555, 0.529 and 0.638, for lipemic, icteric and hemolyzed samples, respectively. The precision for automated detection was high for all interferences, with the exception of samples being only slightly lipemic. The best overall agreement between observers was present in assessing lipemia (mean weighted kappa=0.698), whereas the lowest degree of agreement was observed in assessing icterus (mean weighted kappa=0.476). CONCLUSIONS Visual inspection of lipemic, icteric and hemolyzed samples is highly unreliable and should be replaced by automated systems that report serum indices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Qualitative and Quantitative Approaches for Determination of Hemolyzed Serum

Abstract Background and Objective: Prevention of medical laboratory errors is a major goal of quality control programs. Hemolyzed specimen is one of the common issues causing medical laboratory errors. Apart from the visual assessment, the measurement of serum hemoglobin concentration can be another method to evaluate the intensity of hemolysis. We aimed to assess hemolyzed serum s...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes.

We evaluated the effect of hemolysis, icteric discoloration, lipemia, paraproteinemia, and uremia on enzymatic methods for determining sodium, potassium, and chloride, according to the National Committee for Clinical Laboratory Standards EP7-P proposals for testing interference from endogenous substances. The sodium, potassium, and chloride assays (reagent kits supplied by Boehringer Mannheim) ...

متن کامل

Separation and Determination of the Total Globulins of Human Serum.

A method for isolation and determination of total globulins of human serum, carried out in a single tube without transfer, is described. Serum is treated with 2% (w/v) TCA in ethanol at room temperature to precipitate the globulins quantitatively as a gelatinous white precipitate easily recovered by centrifugation. The supernatant fluid is discarded and the precipitate washed with 2% TCA in eth...

متن کامل

Comparison of Two Flow Cytometric Methods for Detection of Human Invariant Natural Killer T Cells (iNKT)

Background: Invariant natural killer cells (iNKT) are an important immunoregulatory T cell subset. Currently several flow cytometry-based approaches exist for the identifi-cation of iNKT cells, which rely on using the 6B11 monoclonal antibody or a combina-tion of anti-Vα24 and anti-Vβ11 antibodies. Objective: The aim of this study was to compare the ability of two flow cytometry-based methods f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 47 11  شماره 

صفحات  -

تاریخ انتشار 2009