Trocar site hernia on an 8-mm port following robotic-assisted hysterectomy.
نویسندگان
چکیده
The increasing use of laparoscopy has resulted in added complications specific to the laparoscopic approach, such as trocar site hernia (TSH), which is an uncommon but well-recognized problem for both regular laparoscopic and robotic-assisted laparoscopic procedures. We describe an extremely rare case of TSH at an 8-mm port site occurring a relatively short time after surgery in a 53-year-old patient undergoing robotic-assisted laparoscopic hysterectomy for benign reasons. Additionally, this report attempts to explain the possible etiological factors relating to TSH following robotic-assisted surgery. According to our case report, a defect in the 8-mm port that may lead to hernia is one possible explanation, and closure of the 8-mm trocar sites' fascia may be a safer approach during robotic-assisted surgery. Additional reports are needed to accurately determine the frequency of occurrence and importance of this complication.
منابع مشابه
CASE REPORT Richter’s hernia following operative laparoscopy
An obese 50-year-old lady underwent laparoscopicassisted vaginal hysterectomy and laparoscopic bilateral salpingo-oöphorectomy using our routine three-port technique (a subumbilical 10-mm port and two 12-mm lateral ports). The postoperative period was uneventful. On the 12th postoperative day the patient left the UK on a business trip to France. She returned three days later with vomiting once ...
متن کاملIncarcerated Right Lateral Trocar-Site Hernia as a Rare Complication of Robot-Assisted Laparoscopic Prostatectomy
Background: Trocar-site hernia (TSH) is an uncommon complication following laparoscopic surgery and a potential cause of significant morbidity if bowel incarceration or strangulation occurs. Lateral trocar sites are intrinsically less susceptible to hernia development and traditionally do not mandate fascial closure. We present an unusual case involving an incarcerated TSH from a 12-mm right la...
متن کاملAn Unusual Trocar Site Hernia after Prostatectomy
Trocar site hernias are rare complications after laparoscopic surgery but most commonly occur at larger trocar sites placed at the umbilicus. With increased utilization of the laparoscopic approach the incidence of trocar site hernia is increasing. We report a case of a trocar site hernia following an otherwise uncomplicated robotic prostatectomy at a 12 mm right lower quadrant port. The vermif...
متن کاملPrevention of Trocar Site Incisional Hernia Following Laparoscopic Ventral Hernia Repair
BACKGROUND AND OBJECTIVES Trocar-site incisional hernia following laparoscopic ventral hernia repair is reported to have a relatively high incidence. The main reasons are trocar diameter and design, pre-existing fascial defects, and some operation- and patient-related factors. The aim of this article to show a new technique of ventral hernia repair that could prevent trocar site incisional hern...
متن کامل5-Millimeter Trocar-Site Bowel Herniation Following Laparoscopic Surgery
BACKGROUND AND OBJECTIVES This is a case report of a 5-mm trocar-site large bowel herniation following laparoscopic tubal sterilization. During laparoscopic sterilization, the 5-mm port site was closed initially. Large bowel herniation was recognized at the end of the case and managed immediately by laparoscopically reducing the hernia and closing the port site without any short- or long-term c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Chinese Medical Association : JCMA
دوره 77 2 شماره
صفحات -
تاریخ انتشار 2014