Automated three-dimensional quantification of noncalcified coronary plaque from coronary CT angiography: comparison with intravascular US.

نویسندگان

  • Damini Dey
  • Tiziano Schepis
  • Mohamed Marwan
  • Piotr J Slomka
  • Daniel S Berman
  • Stephan Achenbach
چکیده

PURPOSE To determine the accuracy of a previously developed automated algorithm (AUTOPLAQ [APQ]) for rapid volumetric quantification of noncalcified and calcified plaque from coronary computed tomographic (CT) angiography in comparison with intravascular ultrasonography (US). MATERIALS AND METHODS This study was approved by the institutional review board and was HIPAA compliant; all patients provided written informed consent. APQ combines derived scan-specific attenuation threshold levels for lumen, plaque, and knowledge-based segmentation of coronary arteries for quantification of plaque components. APQ was validated with retrospective analysis of 22 coronary atherosclerotic plaques in 20 patients imaged with coronary CT angiography and intravascular US within 2 days of each other. Coronary CT angiographic data were acquired by using dual-source CT. For each patient, well-defined plaques without calcifications were selected, and plaque volume was measured with APQ and manual tracing at CT and with intravascular US. Measurements were compared with paired t test, correlation, and Bland-Altman analysis. RESULTS There was excellent correlation between noncalcified plaque volumes quantified with APQ and intravascular US (r = 0.94, P < .001), with no significant differences (P = .08). Mean plaque volume with intravascular US was 105.9 mm³ ± 83.5 (standard deviation) and with APQ was 116.6 mm³ ± 80.1. Mean plaque volume with manual tracing from CT was 100.8 mm³ ± 81.7 and with APQ was 116.6 mm³ ± 80.1, with excellent correlation (r = 0.92, P < .001) and no significant differences (P = .23). CONCLUSION Automated scan-specific threshold level-based quantification of plaque components from coronary CT angiography allows rapid, accurate measurement of noncalcified plaque volumes, compared with intravascular US, and requires a fraction of the time needed for manual analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of coronary plaque morphology by contrast-enhanced computed tomographic angiography: comparison with intravascular ultrasound.

BACKGROUND Computed tomographic (CT) angiography provides accurate noninvasive assessment for coronary artery stenosis. The ability of CT angiography to determine plaque morphology remains unclear. METHODS Twelve patients undergoing intravascular ultrasound for clinical indications underwent CT angiography for the evaluation of plaque morphology. Plaque morphology was classified as (1) soft, ...

متن کامل

Prospective validation of standardized, 3-dimensional, quantitative coronary computed tomographic plaque measurements using radiofrequency backscatter intravascular ultrasound as reference standard in intermediate coronary arterial lesions: results from the ATLANTA (assessment of tissue characteristics, lesion morphology, and hemodynamics by angiography with fractional flow reserve, intravascular ultrasound and virtual histology, and noninvasive computed tomography in atherosclerotic plaques) I study.

OBJECTIVES This study sought to determine the accuracy of 3-dimensional, quantitative measurements of coronary plaque by computed tomography angiography (CTA) against intravascular ultrasound with radiofrequency backscatter analysis (IVUS/VH). BACKGROUND Quantitative, 3-dimensional coronary CTA plaque measurements have not been validated against IVUS/VH. METHODS Sixty patients in a prospect...

متن کامل

Automated quantification of coronary plaque with computed tomography: comparison with intravascular ultrasound using a dedicated registration algorithm for fusion-based quantification.

AIMS Previous studies have used semi-automated approaches for coronary plaque quantification on multi-detector row computed tomography (CT), while an automated quantitative approach using a dedicated registration algorithm is currently lacking. Accordingly, the study aimed to demonstrate the feasibility and accuracy of automated coronary plaque quantification on cardiac CT using dedicated softw...

متن کامل

Low- to high-density lipoprotein cholesterol ratio followed by coronary computed tomography angiography improves coronary plaque classification accuracy

Coronary computed tomography angiography (CCTA) is a noninvasive test for detection and analysis of coronary plaques morphology and classification. The low- to high-density lipoprotein cholesterol (L/H) ratio is associated with plaques vulnerability. The study aims to investigate the diagnostic accuracy of CCTA and L/H ratio for plaques classification. We enrolled 212 patients with coronary art...

متن کامل

Noncalcified atherosclerotic plaque burden at coronary CT angiography: a better predictor of ischemia at stress myocardial perfusion imaging than calcium score and stenosis severity.

OBJECTIVE The purpose of this study was to examine the relation between the coronary CT angiographic findings of calcified and noncalcified plaque burden and stenosis severity and the myocardial perfusion imaging finding of ischemia. MATERIALS AND METHODS Seventy-two patients (41 men, 31 women; mean age, 56 years) underwent coronary CT angiography and stress-rest SPECT myocardial perfusion im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology

دوره 257 2  شماره 

صفحات  -

تاریخ انتشار 2010