CINE-MR imaging of the normal and infarcted rat heart using an 11.7 T vertical bore MR system.
نویسندگان
چکیده
MR imaging is uniquely placed to non-invasively study rodent cardiac structure and function. High-field MR scanners commonly have a vertical bore, and the purpose of this work was to demonstrate CINE-MR imaging in normal and infarcted rat hearts after determining hemodynamic stability when positioned vertically for imaging. Optimisation of imaging parameters was carried out prior to assessment of cardiac function in a group of normal and infarcted rat hearts. Rat hemodynamics were unaltered when vertical for 90 minutes, compared with horizontal measurements and rat cardiac parameters were measured accurately and reproducibly with our optimized CINE-MR protocol. A flip angle of 17.5 degrees was shown to provide optimal contrast for the assessment of structure and function, and, in contrast to our findings in mice, respiratory gating was not found to be essential. Hence, we conclude that vertical bore MR systems can be used to measure in vivo cardiac function in normal and infarcted rat hearts.
منابع مشابه
Stunned, infarcted, and normal myocardium in dogs: simultaneous differentiation by using gadolinium-enhanced cine MR imaging with magnetization transfer contrast.
PURPOSE To simultaneously differentiate stunned, infarcted, and normal myocardial regions by using gadolinium-enhanced cine magnetic resonance (MR) imaging with magnetization transfer contrast. MATERIALS AND METHODS Twelve dogs were imaged on days 1 and 8 after transient 90-minute coronary artery occlusion. A magnetization transfer contrast with echo-train readout (MTET) MR sequence was perfo...
متن کاملAccelerating cine-MR Imaging in Mouse Hearts Using Compressed Sensing
PURPOSE To combine global cardiac function imaging with compressed sensing (CS) in order to reduce scan time and to validate this technique in normal mouse hearts and in a murine model of chronic myocardial infarction. MATERIALS AND METHODS To determine the maximally achievable acceleration factor, fully acquired cine data, obtained in sham and chronically infarcted (MI) mouse hearts were 2-4...
متن کاملQuantitative MR measurements of regional and global left ventricular function and strain after intramyocardial transfer of VM202 into infarcted swine myocardium.
Previous studies have shown the beneficial effects of the hepatocyte growth factor (HGF) gene on myocardial perfusion and infarction size but not on the regional strain in relationship to global left ventricular function. A noninvasive magnetic resonance (MR) study was performed to determine the effect of a new HGF gene, VM202, expressing two isoforms of HGF, on regional and global left ventric...
متن کاملCine and tagged cardiovascular magnetic resonance imaging in normal rat at 1.5 T: a rest and stress study
BACKGROUND The purpose of this study was to measure regional contractile function in the normal rat using cardiac cine and tagged cardiovascular magnetic resonance (CMR) during incremental low doses of dobutamine and at rest. METHODS Five rats were investigated for invasive left ventricle pressure measurements and five additional rats were imaged on a clinical 1.5 T MR system using a cine seq...
متن کاملHigh-Field Open versus Short-Bore Magnetic Resonance Imaging of the Spine: A Randomized Controlled Comparison of Image Quality
BACKGROUND The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. METHODS Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 8 2 شماره
صفحات -
تاریخ انتشار 2006