Uncertainty estimation for temperature measurement with diagnostic ultrasound

نویسندگان

  • Tina A. Fuhrmann
  • Olga Georg
  • Julian Haller
  • Klaus-V. Jenderka
  • Volker Wilkens
چکیده

BACKGROUND Ultrasound therapies are promising, non-invasive applications with potential to significantly improve, e.g. cancer therapies like viro- or immunotherapy or surgical applications. However, a crucial step towards their breakthrough is still missing: affordable and easy-to-handle quality assurance tools for therapy devices and ways to verify treatment planning algorithms. This deficiency limits the safety and comparability of treatments. METHODS To overcome this deficiency accurate spatial and temporal temperature maps could be used. In this paper, the suitability of temperature calculation based on time-shifts of diagnostic ultrasound backscattered signals (echo-time-shift) is investigated and associated uncertainties are estimated. Different analysis variations were used to calculate the time-shifts: discrete and continuous methods as well as different frames as a reference for temperature calculation (4 s before, 16 s before the frame of interest, base frame). A sigmoid function was fitted and used to calculate temperatures. Two-dimensional temperature maps recorded during and after therapeutic ultrasound sonication were examined. All experiments were performed in agar-graphite phantoms mimicking non-fatty tissue, with high-intensity focused ultrasound being the source of heating. RESULTS Continuous methods are more accurate than discrete ones, and uncertainties of calculated temperatures are in general lower, the earlier the reference frame was recorded. Depending on the purpose of the measurement, a compromise has to be made between the following: calculation accuracy (early reference frame), tolerance towards small movements (late reference frame), reproducing large temperature changes or cooling processes (reference frame at a certain point in time), speed of the algorithm (discrete (fast) vs. continuous (slower) shift calculation), and spatial accuracy (interval size for index-shift calculation). Within the range from 20 °C to 44 °C, uncertainties as low as 12.4 % are possible, being mainly due to medium properties. CONCLUSIONS Temperature measurements using the echo-time-shift method might be useful for validation of treatment plan algorithms. This might also be a comparatively accurate, fast, and affordable method for laboratory and clinical quality assessment. Further research is necessary to improve filter algorithms and to extend this method to multiple foci and the usage of temperature-dependent tissue quantities. We used an analytical approach to investigate the uncertainties of temperature measurement. Different analysis variations are compared to determine temperature distribution and development over time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Logistic discriminant analysis of breast cancer using ultrasound measurements

Background: Logistic discriminant method was applied to differentiate malignant from benign in a group of patients with proved breast lesions on the basis of ultrasonic parameters. Materials and Methods: Our database include 273 patients' ultrasonographic pictures consisting of 14 quantitative variables. The measured variables were ultrasound propagation velocity, acoustic impedence and attenua...

متن کامل

Relative brightness due to temperature changes with ultrasound image analysis during Radiofrequency ablation

Introduction: Diagnosis of primary and secondary cancers to treat patients with diffuse and malignant tumors is an important subject. The appropriate treatment will be eliminating primary and metastatic tumors. Radiofrequency ablation with localized heat induction in the target tissue causes irreversible cellular damage and tissue coagulation. Estimation of tissue temperature c...

متن کامل

Measurement of Heat Characteristics of a New Incubator with a Chemical Energy Source

A heat transfer model was developed for a new non-electric infant’s transport incubator. The source of heat comprises a super saturated solution of Sodium Acetate and a metal disk (activator) in a plastic container. Estimating the number of the chemical bags required for different ambient temperature was the goal. First the quantity of heat generated by the chemical was appointed through experi...

متن کامل

In vivo noninvasive temperature measurement by B-mode ultrasound imaging.

OBJECTIVE This study investigated the use of ultrasound image analysis in quantifying temperature changes in tissue, both ex vivo and in vivo, undergoing local hyperthermia. METHODS Temperature estimation is based on the thermal dependence of the acoustic speed in a heated medium. Because standard beam-forming algorithms on clinical ultrasound scanners assume a constant acoustic speed, temper...

متن کامل

Uncertainty evaluation of dead zone of diagnostic ultrasound equipment

This paper presents a model for evaluating measurement uncertainty of a feature used in the assessment of ultrasound images: dead zone. The dead zone was measured by two technicians of the INMETRO’s Laboratory of Ultrasound using a phantom and following the standard IEC/TS 61390. The uncertainty model was proposed based on the Guide to the Expression of Uncertainty in Measurement. For the teste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016