A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series.
نویسندگان
چکیده
A 3D sequence for dynamic susceptibility imaging is proposed which combines echo-shifting principles (such as PRESTO), sensitivity encoding (SENSE), and partial-Fourier acquisition. The method uses a moderate SENSE factor of 2 and takes advantage of an alternating partial k-space acquisition in the "slow" phase encode direction allowing an iterative reconstruction using high-resolution phase estimates. Offering an isotropic spatial resolution of 4 x 4 x 4 mm(3), the novel sequence covers the whole brain including parts of the cerebellum in 0.5 sec. Its temporal signal stability is comparable to that of a full-Fourier, full-FOV EPI sequence having the same dynamic scan time but much less brain coverage. Initial functional MRI experiments showed consistent activation in the motor cortex with an average signal change slightly less than that of EPI.
منابع مشابه
A Rapid 3D Partial-Fourier PRESTO-SENSE Method for Functional Motor MRI
Introduction: High temporal resolution is necessary for an accurate determination of the hemodynamic response to functional stimuli [1]. At the same time high volume coverage is desirable to allow an examination of temporal relations between different brain regions involved in performing a task. Partial-Fourier PRESTO-SENSE [2] seems to be a good candidate for event related fMRI studies because...
متن کاملThe PRESTO technique for fMRI
In the early days of BOLD fMRI, the acquisition of T(2)(*) weighted data was greatly facilitated by rapid scan techniques such as EPI. The latter, however, was only available on a few MRI systems that were equipped with specialized hardware that allowed rapid switching of the imaging gradients. For this reason, soon after the invention of fMRI, the scan technique PRESTO was developed to make ra...
متن کاملOn The Simulation of Partial Differential Equations Using the Hybrid of Fourier Transform and Homotopy Perturbation Method
In the present work, a hybrid of Fourier transform and homotopy perturbation method is developed for solving the non-homogeneous partial differential equations with variable coefficients. The Fourier transform is employed with combination of homotopy perturbation method (HPM), the so called Fourier transform homotopy perturbation method (FTHPM) to solve the partial differential equations. The c...
متن کاملCompressed sensing MRI combined with SENSE in partial k-space.
Compressed sensing (CS), parallel imaging and partial Fourier (PF) acquisition are all effective methods to reduce k-space sampling and therefore accelerate MR acquisition. The combined use of these methods gives us more options to balance the needs for scan speed and image quality. We conducted simulations on full k-space data to demonstrate the potential use of combining CS-SENSE with PF acqu...
متن کاملSimultaneous Time Interleaved MultiSlice (STIMS) for Rapid Susceptibility Weighted acquisition
T2* weighted 3D Gradient Echo (GRE) acquisition is the main sequence used for Susceptibility Weighted Imaging (SWI) and Quantitative Susceptibility Mapping (QSM). These applications require a long echo time (TE) to build up phase contrast, requiring a long repetition time (TR), and leading to excessively lengthy scans. The long TE acquisition creates a significant amount of unused time within e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 50 4 شماره
صفحات -