Effects of Target Size and Test Distance on Stereoacuity
نویسندگان
چکیده
Target size and test distance effects on stereoacuity were investigated in 24 subjects using a three-dimensional monitor. Examination 1: Target Size Effects. The test distance was 2.5 m for 0.1°, 0.2°, 0.5°, and 0.9° target sizes; crossed parallax was presented in 22-second units. Average stereoacuity values for 0.1°, 0.2°, 0.5°, and 0.9° target sizes were 59.58 ± 14.86, 47.66 ± 13.71, 41.25 ± 15.95, and 39.41 ± 15.52 seconds, respectively. Stereoacuity was significantly worse with a 0.1° target than with 0.2°, 0.5°, and 0.9° target sizes (P = 0.03, P < 0.0001, and P < 0.0001, resp.). Examination 2: Test Distance Effects. Test distances of 2.5, 5.0, and 7.5 m were investigated for a 0.5° target size; crossed parallax was presented in 22-second units. Average stereoacuity values at 2.5 m, 5.0 m, and 7.5 m test distances were 44.91 ± 16.16, 34.83 ± 10.84, and 24.75 ± 7.27 seconds, respectively. Stereoacuity at a 7.5 m distance was significantly better than at distances of 2.5 m and 5.0 m (P < 0.0001 and P = 0.02, resp.). Stereoacuity at a 5.0 m distance was significantly better than at 2.5 m (P = 0.04). Stereoacuity should be estimated by both parallax and other elements, including test distance and target size.
منابع مشابه
Evaluating stereoacuity with 3D shutter glasses technology
BACKGROUND To determine the stereoacuity threshold with a 3D laptop equipped with 3D shutter glasses, and to evaluate the effect of different shape and size of test symbols and different type of disparities to stereoacuity. METHODS Thirty subjects with a visual acuity in each eye of at least 0 logMAR and a stereoacuity of at least 32 arcsec (as assessed in Fly Stereo Acuity Test) were recruit...
متن کاملVariability of stereoacuity in intermittent exotropia.
PURPOSE Distance stereoacuity is used to monitor deterioration of intermittent exotropia (IXT), but variability of stereoacuity has not been studied rigorously. The purpose of this study was to assess the variability of stereoacuity over one day in children with IXT. DESIGN Prospective cohort study. METHODS Twelve children with IXT were recruited. Stereoacuity was assessed using the Frisby ...
متن کاملFrisby Davis distance stereoacuity values in visually normal children.
AIMS To establish the range of normal distance stereoacuity in young children using the Frisby Davis distance stereo test (FD2). METHODS Children passing preschool vision screening assessments underwent measurement of distance stereoacuity with the FD2 using a standard testing protocol. RESULTS 59 visually normal children aged between 36 months and 68 months were recruited to this study. Al...
متن کاملDevelopment of a Novel Stereoacuity Test Device Using a High-Resolution 3D Monitor
Purpose: To develop stereoacuity test using a high-resolution 3D monitor and examined the effects of the monitor on the measured stereoacuity. Methods: We conducted stereoacuity test using a high-resolution 3D monitor. This 3D monitor can show parallax of 27 s (crossed) at the minimum at measurement distance 40 cm, and circularly polarized glasses were used for binocular separation. Titmus ster...
متن کاملDistance stereotesting using vision test charts for intermittent exotropia
PURPOSE To assess the role of distance stereoacuity using the System Chart SC-1600 Pola (SC) to evaluate intermittent exotropia (IXT). METHODS Stereoacuity testing was performed in 28 children with IXT and 25 age-matched control subjects using the SC test, the distance Randot stereotest for distance, and the Titmus stereotest for near stereoacuity. Ocular alignment control was defined using t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016