Comparisonof Per - cent of ExpectedValue and Percent Recoveryfor Serum Folate Radioassay

نویسندگان

  • Joseph Tesfaye
  • Jacques Longpre
  • Frank Bodley
  • Sigrid Klotzsch
چکیده

The LKB 8600 Reaction Rate Analyzer sold in the United States, is equipped with a “delay switch,” whereas the same instrument sold in Canada measures time rate reactions immediately after the addition of the initiating reagent, without provision for delay. Therefore, “lag-phases” of any enzyme reaction are recorded with the Canadian version. One of the basics of zero-order kinetic assays is the measurement of the linear phase of reaction. This rule cannot be observed if an instrument such as the LKB 8600 is used without a modification to permit delayed measurements. Both CPK and LDH determinations may give erroneously high results in such a system, especially if a computer printout is used. Boebringer Mannheim has investigated the possibilities of shortening the “lag-phase” for CPK determinations. It was found that the use of chromatographically pure creatine phosphate in the assay reduces the phase to less than 1 minute, but costs increase four to five times. To rectify the problem for routine laboratory, the following steps have been taken: 1. Since July 1971, Canadian customers who use the CPK kit (BMC Cat. No. 15926) with the LKB 8600 are given ATP-free creatine phosphate free of charge. 2. During 1972, a new CPK test kit (BMC Cat. No. 15721) was introduced, especially designed for the use with the LKB 8600 and other automated instruments. This kit contains ATP-free creatine phosphate of the highest purity. We must emphasize that our Test Combination (BMC Cat. No. 15926) for the determination of CPK activity does give correct results when used according to the printed insert. The methodology is based on proposals made by Rosalki. Any modification to the operating instructions should first be discussed with our Technical Services Department. It is regretful that often attempts to economize the work-load results in over-asking for the possibilities df the given instrument-reagent combinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical evaluation of a folate radioassay: application to serum and erythrocyte measurements.

Many commercial folate radioassay kits have proven to be unsatisfactory in the past. It has been found that the Schwarz/Mann Iodine-125 folate radioassay kit permits a rapid measurement of folic acid requiring only a single incubation at pH 9.3. At this pH, the relative affinity of pteroylglutamic acid (FA) and N-5-methyltetrahydrofolic acid (MTFA) for the milk binder is the same. Additionally,...

متن کامل

Clinical and laboratory observations on serum folate-binding protein.

We studied the effect of serum folate-binding protein (FBP) on folate radioassays and the relationship of the serum level of unsaturated FBP to the serum folate level in various clinical states. Our modification of a heat-extracted radioassay was compared to a whole serum radioassay. Our results confirmed the existence of elevated serum levels of unsaturated FBP in some normal subjects, in some...

متن کامل

Radioassay of serum folate.

We describe a radioassay procedure for serum folate, in which commercially available crystalline 3lactoglobulirt is used as the folate-binding agent. The folate binders present in serum are eliminated by heating serum in a boiling water bath for 15 mm to denature the proteins. Radioassayable serum folate is shown to be stable under these conditions, and the results for folate compare well with ...

متن کامل

Radioassay of serum folate, with use of a serum blank and nondialyzed milk as folate binder.

Serum folate determination by this method requires incubation of 0.1 ml of serum (or standards) with nondialyzed milk and then with tritium-labeled folate. A serum blank corrects for nonspecific binders present in the serum. Unbound folate is removed with hemoglobin-coated charcoal. The standard deviation of the results is ±G.2 pig/liter, and more than 90% of folate added to the serum is accoun...

متن کامل

Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood.

We compared results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested...

متن کامل