Correlation between volume of herniated orbital contents and the amount of enophthalmos in orbital floor and wall fractures.

نویسندگان

  • Zhiyong Zhang
  • Yi Zhang
  • Yang He
  • Jinggang An
  • Roger Arthur Zwahlen
چکیده

PURPOSE To analyze the correlation between the volume of herniated orbital contents and the amount of enophthalmos in orbital floor and wall fractures. MATERIALS AND METHODS Patients with secondary enophthalmos due to unilateral orbital floor and wall fractures were recruited. Computed tomography-assisted measurements of both orbits as well as of the amount of enophthalmos were performed. The following volumes were calculated: 1) the overall volume of both the healthy and fractured orbit, 2) the volume of herniated orbital contents at the orbital walls, 3) the volume of herniated orbital contents anterior and posterior to the vertical eyeball equator. The amount of enophthalmos was also measured by computed tomography. Multifactor linear regression analysis was performed to obtain correlations between the amount of enophthalmos and the measured volumes. RESULTS Twenty-three patients were included. The average enophthalmos was 4.0 mm (SD = 1.49). Although correlation between volume differences of healthy and fractured sides was not statistically significant, the overall volume of the herniated orbital contents was significantly correlated (P < .05) with the amount of enophthalmos. Regarding the specific orbital sites of herniation, the orbital floor was detected to be most significantly correlated to the amount of enophthalmos (P < .05), although only the herniation posterior to the vertical eyeball equator. CONCLUSION The overall volume of herniated orbital contents correlated significantly with the amount of enophthalmos. The orbital floor was detected to be the site most significantly correlated with the amount of enophthalmos (although only if herniation occurred posterior to the vertical eyeball equator). Only the volume of herniated soft tissues posterior to the eyeball equator showed correlation with the amount of enophthalmos.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct oblique sagittal CT of orbital wall fractures.

Direct oblique sagittal CT was used to evaluate trauma to 77 orbits. Sixty-seven orbital wall fractures with intact orbital rims (36 floor, 22 medial wall, nine roof) were identified in 47 orbits. Since persistent diplopia and/or enophthalmos may warrant surgical repair of orbital floor fractures, optimal imaging should include an evaluation of extraocular muscle status, the nature and amount o...

متن کامل

Correlation between the 2-Dimensional Extent of Orbital Defects and the 3-Dimensional Volume of Herniated Orbital Content in Patients with Isolated Orbital Wall Fractures

BACKGROUND The purpose of this study was to assess the correlation between the 2-dimensional (2D) extent of orbital defects and the 3-dimensional (3D) volume of herniated orbital content in patients with an orbital wall fracture. METHODS This retrospective study was based on the medical records and radiologic data of 60 patients from January 2014 to June 2016 for a unilateral isolated orbital...

متن کامل

Inferior Blow-Out Fracture Reduction Using Two Urinary Balloon Catheters

BACKGROUND The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. METHODS A retrospective review was performed for all patients with ...

متن کامل

Reconstruction of orbital floor fractures with maxillary bone.

OBJECTIVE To evaluate the use of autogenous maxillary bone for the repair of orbital floor defects secondary to blunt facial trauma. DESIGN Retrospective case series of 41 patients with a mean follow-up of 1.7 years. SETTING Major metropolitan teaching hospital. PATIENTS Forty-one consecutive patients who underwent repair of orbital floor fractures with maxillary antral wall bone grafts. ...

متن کامل

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

BACKGROUND The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. METHODS Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 2012