Subchondral screw fixation for femoral neck fractures.
نویسندگان
چکیده
We describe a method of internal fixation for femoral neck fractures which has been newly developed to reduce the frequency of early complications. Two cannulated screws are inserted in the axis of the femoral neck to reach into the subchondral bone of the femoral head. The screws are inserted over guide pins and the tip of the screw is self-tapping and designed to provide good anchorage in the femoral head. We used this method in 44 consecutive patients in a prospective study with no exclusions, followed for a minimum of 24 months. All fractures healed within 12 months, and there were no cases of early loosening or nonunion. In four cases, late segmental collapse had developed during the mean follow-up period of 30 months.
منابع مشابه
Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration.
BACKGROUND Intracapsular femoral neck fractures are associated with high rates of nonunion. We aimed to identify risk factors for nonunion in patients with both displaced and nondisplaced intracapsular femoral neck fractures treated with three 7-mm parallel cannulated screws, placed in either a triangle or an inverted triangle configuration, using failure of fixation as the primary outcome. M...
متن کاملA case report of Progressive subluxation leading to an anterior dislocation of the hip following sliding hip screw fixation for pertrochanteric Extracapsular 4 part fracture neck of femur
Unstable 4 part pertrochanteric fractures without lateral cortical support presents considerable technical problem in treatment with high risk of failure with any implant. Anatomical or slight valgus reduction and subchondral central position of the lag screw (TAD <25 mm) reduces the chance of screw cut out and other complications.
متن کاملComparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures
Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...
متن کاملTreatment of femoral fracture through the sliding screw portal following fixation of the femoral neck fracture.
The authors report a case of secondary femoral fracture through the sliding hip screw portal following fixation of the femoral neck fracture. The femoral neck and subtrochanteric fracture was successfully treated by superimposing a trochanteric stabilization plate (TSP) onto the regular sliding hip screw.
متن کاملSubtrochanteric fracture: a rare but severe complication after screw fixation of femoral neck fractures in the elderly.
Cannulated screw fixation is a minimal invasive technique to treat undisplaced femoral neck fractures. It is the preferred method in elderly patients who often suffer co-morbidities. There is scarce literature on subtrochanteric femoral fracture as a complication of cannulated screw fixation of a femoral neck fracture. This complication occurred, without an adequate trauma, in two of 35 patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 71 2 شماره
صفحات -
تاریخ انتشار 1989