Low-dose multidetector CT angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease.
نویسندگان
چکیده
PURPOSE To investigate the ionizing radiation dose, image quality, and diagnostic performance of computed tomographic (CT) angiography of the peripheral arteries with three different CT angiographic acquisition protocols, with use of pretreatment digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS The study was approved by the institutional review board and performed in agreement with the 1990 Declaration of Helsinki and subsequent amendments. Each patient provided informed consent before undergoing CT. The authors performed a prospective, single-center, randomized comparison of three different x-ray exposure CT acquisition protocols in 60 randomized patients with peripheral arterial occlusive disease referred for 64-section multidetector CT angiography of the lower limb (0.625-mm collimation, intravenous administration of 100 mL of iomeprol [400 mg iodine per milliliter] at 4 mL/sec). The acquisition protocols were performed with (a) 120 kVp and a noise index of 26 (moderate noise reduction [MNR]), referred to as the 120-kVp MNR group; (b) 80 kVp and a noise index of 26, referred to as the 80-kVp MNR group; and (c) 80 kVp and a noise index of 30 (high noise reduction [HNR]), referred to as the 80-kVp HNR group. Axial and three-dimensional (3D) images were qualitatively and quantitatively compared by using the overall F test and pairwise comparisons. The X(2) test was used to compare the three protocols in terms of diagnostic performance in patients who also underwent DSA before an interventional procedure. RESULTS Significantly higher attenuation values were obtained in the vessels with the 80-kVp MNR and 80-kVp HNR acquisition protocols. No significant differences were noted in terms of image quality with either axial source images or 3D reconstructions. Likewise, no significant differences were found among the three protocols in terms of noise throughout the peripheral vasculature. Finally, no significant differences were found among the three groups with regard to diagnostic performance. Overall dose reductions of 48% and 61% were obtained for the 80-kVp MNR and 80-kVp HNR protocols, respectively. CONCLUSION Substantial reductions of radiation dose are achievable at multidetector CT angiography of the peripheral arteries without compromising image quality and diagnostic performance if acquisition protocols are modified appropriately and used in conjunction with a contrast material containing a high concentration of iodine.
منابع مشابه
Low radiation dose subtraction CT angiography (CTA) for diagnosis of peripheral arterial occlusive disease
متن کامل
Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملRole of CT Angiography & Colour Flow Imaging (USG) in Evaluation of Peripheral Arterial Diseases
Purpose: To compare multidetector computed tomography (MDCT) angiography &colour flow imaging (USG)in evaluation of patients with peripheral arterialdiseases. Also evaluate the role MDCT in providing information regarding collateral circulation in peripheral arterial diseases and aiding treatment planning in peripheral arterial diseases. Material and methods: CT angiography performed with “Bril...
متن کاملUltra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic angiography.
OBJECTIVES This study sought to evaluate the feasibility of using ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic (CT) angiography to follow diagnostic cardiac catheterization. BACKGROUND Cardiovascular interventions such as percutaneous aortic valve replacement require transfemoral delivery of large-bore intra-arterial catheters; therefore, pre-procedura...
متن کاملAcquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent
Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiology
دوره 263 1 شماره
صفحات -
تاریخ انتشار 2012