Preparation and Calibration of Carrier-Free 209Po Solution Standards
نویسندگان
چکیده
Carrier-free 209Po solution standards have been prepared and calibrated. The standards, which will be disseminated by the National Institute of Standards and Technology as Standard Reference Material SRM 4326, consist of (5.1597 ±0.0024) g of a solution of polonium in nominal 2 mol · L-1 hydrochloric acid (having a solution density of (1.031±0.004) g · mL-1 at 22 °C) that is contained in 5 mL flame-sealed borosilicate glass ampoules, and are certified to contain a 209Po alpha-particle emission rate concentration of (85.42±0.29) s-1 · g-1 (corresponding to a 209Po activity concentration of (85.83 ±0.30) Bq · g-1) as of the reference time of 1200 EST 15 March 1994. The calibration was based on 4πα liquid scintillation (LS) measurements with two different LS counting systems and under wide variations in measurement and sample conditions. Confirmatory measurements by 2πα gas-flow proportional counting were also performed. The only known radionuclidic impurity, based on α- and photon-emission spectrometry, is a trace quantity of 208Po. The 208Po to 209Po impurity ratio as of the reference time was 0.00124 ±0.00020. All of the above cited uncertainty intervals correspond to a combined standard uncertainty multiplied by a coverage factor of k = 2. Although 209Po is nearly a pure α emitter with only a weak electron capture branch to 209Bi, LS measurements of the 209Po a decay are confounded by an a transition to a 2.3 keV ( Jπ= 1/2-) level in 205Pb which was previously unknown to be a delayed isomeric state.
منابع مشابه
Numerical Study on Resistance of a Bulk Carrier Vessel Using CFD Method
Bulk carriers have an important role in international maritime transport. In this paper, we carried out a numerical study on a model of bulk carrier vessel and calculated total resistance of the model. A model of a bulk carrier vessel with length of 2.76 m, breadth of 0.403 m and draught of 0.173 m was selected for numerical modeling. Numerical work was done by commercial CFD software ANSY...
متن کاملSurface-initiated Atom Transfer Radical Polymerization and Solution Intercalation Methods for Preparation of Cellulose-G-PS-G-PAN/MMT Bionanocomposite
Cellulose was modified by polystyrene (PS) and polyacrylonitrile (PAN) via free radical and living radical polymerization, and then cellulose was used as the matrix in the preparation of polymer/clay nanocomposite, through a solution intercalation method. For this purpose, first, the graft polymerization of styrene (St) onto cellulose fibers was performed by using suspension polymerization and ...
متن کاملPreparation of Reactive and Thermal Stable Hyperbranched Graft Copolymers/ Clay Nanocomposite via ‘Living’ Free Radical Polymerization
Exfoliated poly (Chloromethyl styrene-co-styrene)-g-polyacrylonitryle/organo- modified montmorillonite [P(CMSt-co-St)-g-PAN/O-MMT] nanocomposite was synthesized through solution intercalation method by using atom transfer and nitroxide mediated radical polymerization. At first, poly (chloromethyl styrene-costyrene) copolymer was synthesized by nitroxide - mediated “living” free radical polyme...
متن کاملValidation of a fully automated robotic setup for preparation of whole blood samples for LC-MS toxicology analysis.
A fully automated setup was developed for preparing whole blood samples using a Tecan Evo workstation. By integrating several add-ons to the robotic platform, the flexible setup was able to prepare samples from sample tubes to a 96-well sample plate ready for injection on liquid chromatography-mass spectrometry using several preparation techniques, including protein precipitation, solid-phase e...
متن کاملQUANTIFICATION OF GALLIUM IN DRIED RESIDUE SAMPLES BY XRF: AN IMPROVED SAMPLE PREPARATION METHOD FOR ANALYZING PLUTONIUM METAL, C.G. Worley, pp. 421-426
A novel XRF sample preparation method was investigated to quantify the concentration of gallium in plutonium metal and minimize the possibility of contaminating the instrument with radioactive material. To prepare homogenous specimens and to add an internal standard, the plutonium must first be dissolved. The currently established method then entails removing the plutonium by chromatography and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 100 شماره
صفحات -
تاریخ انتشار 1995