Implantable cardioverter-defibrillators and prevention of sudden cardiac death in hypertrophic cardiomyopathy.
نویسندگان
چکیده
CONTEXT Recently, the implantable cardioverter-defibrillator (ICD) has been promoted for prevention of sudden death in hypertrophic cardiomyopathy (HCM). However, the effectiveness and appropriate selection of patients for this therapy is incompletely resolved. OBJECTIVE To study the relationship between clinical risk profile and incidence and efficacy of ICD intervention in HCM. DESIGN, SETTING, AND PATIENTS Multicenter registry study of ICDs implanted between 1986 and 2003 in 506 unrelated patients with HCM. Patients were judged to be at high risk for sudden death; had received ICDs; underwent evaluation at 42 referral and nonreferral institutions in the United States, Europe, and Australia; and had a mean follow-up of 3.7 (SD, 2.8) years. Measured risk factors for sudden death included family history of sudden death, massive left ventricular hypertrophy, nonsustained ventricular tachycardia on Holter monitoring, and unexplained prior syncope. MAIN OUTCOME MEASURE Appropriate ICD intervention terminating ventricular tachycardia or fibrillation. RESULTS The 506 patients were predominately young (mean age, 42 [SD, 17] years) at implantation, and most (439 [87%]) had no or only mildly limiting symptoms. ICD interventions appropriately terminated ventricular tachycardia/fibrillation in 103 patients (20%). Intervention rates were 10.6% per year for secondary prevention after cardiac arrest (5-year cumulative probability, 39% [SD, 5%]), and 3.6% per year for primary prevention (5-year probability, 17% [SD, 2%]). Time to first appropriate discharge was up to 10 years, with a 27% (SD, 7%) probability 5 years or more after implantation. For primary prevention, 18 of the 51 patients with appropriate ICD interventions (35%) had undergone implantation for only a single risk factor; likelihood of appropriate discharge was similar in patients with 1, 2, or 3 or more risk markers (3.83, 2.65, and 4.82 per 100 person-years, respectively; P = .77). The single sudden death due to an arrhythmia (in the absence of advanced heart failure) resulted from ICD malfunction. ICD complications included inappropriate shocks in 136 patients (27%). CONCLUSIONS In a high-risk HCM cohort, ICD interventions for life-threatening ventricular tachyarrhythmias were frequent and highly effective in restoring normal rhythm. An important proportion of ICD discharges occurred in primary prevention patients who had undergone implantation for a single risk factor. Therefore, a single marker of high risk for sudden death may be sufficient to justify consideration for prophylactic defibrillator implantation in selected patients with HCM.
منابع مشابه
Role of Implantable Cardioverter Defibrillators in the Treatment of Hypertrophic Cardiomyopathy
Hypertrophic cardiomyopathy (HCM) is an important cardiovascular disease with sudden cardiac death as the most devastating presentation. Implantable cardioverter defibrillators (ICD) are the optimal therapy for prevention of sudden death from ventricular tachycardia or fibrillation of any cause. While there is no controversy with implanting ICDs in patients who have already survived a cardiac a...
متن کامل[Cardiac arrest in the pediatric population].
A case of cardiac arrest in a ten year old child that was successfully resuscitated is here presented. The etiological investigation showed an Hypertrophic Cardiomyopathy (HCM). An Implantable Cardioverter Defibrillator (ICD) was placed for secondary profilaxy of Sudden Death (SD). Sudden Death in paediatric age is a rare accident with bad prognosis (survival with no sequel inferior to 5%) and ...
متن کاملLife expectancy gains and cost-effectiveness of implantable cardioverter/defibrillators for the primary prevention of sudden cardiac death in patients with hypertrophic cardiomyopathy
CRD summary The study examined the cost-effectiveness of using implantable cardioverter/defibrillator (ICD) insertion or amiodarone therapy for the prevention of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM), with no history of cardiac arrest but a significant risk of SCD. The study results support the cost-effectiveness of ICD insertion from the perspective of t...
متن کاملLife expectancy gains and cost-effectiveness of implantable cardioverter/defibrillators for the primary prevention of sudden cardiac death in patients with hypertrophic cardiomyopathy
CRD summary The study examined the cost-effectiveness of using implantable cardioverter/defibrillator (ICD) insertion or amiodarone therapy for the prevention of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM), with no history of cardiac arrest but a significant risk of SCD. The study results support the cost-effectiveness of ICD insertion from the perspective of t...
متن کاملLong-Term Survival Following Cardiac Arrest Without Implantable Defibrillator Protection in a Hypertrophic Cardiomyopathy Patient
Hypertrophic cardiomyopathy (HCM) is the most common cause of sudden cardiac death in young people. Implantable cardioverter defibrillator (ICD) is the optimal therapy in patients with HCM, both for primary or secondary prevention of sudden death. Left ventricular systolic function in HCM is usually normal. However, in few patients, HCM has been reported to progress to a state that is character...
متن کاملRisk stratification and prevention of sudden death in hypertrophic cardiomyopathy.
Sudden unexpected death, often occurring in young, asymptomatic patients, is the most devastating facet of the natural history of hypertrophic cardiomyopathy, and appears to be the consequence of primary ventricular tachyarrhythmias arising in an electrically unstable myocardial substrate characterized by disorganized cellular architecture, ischemia, cell death, and replacement scarring. Althou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JAMA
دوره 298 4 شماره
صفحات -
تاریخ انتشار 2007